長方形小線量率フィールドの等価正方形フィールドサイズの定義の評価
Ignasi Méndez1, Mateb Al Khalifa2,3, Haya Aljuaid2
1Department of Dosimetry and Quality of Radiological Procedures, Institute of Oncology Ljubljana, Ljubljana, Slovenia.
Background:
In the IAEA TRS-483 Code of Practice (CoP), rectangular small field sizes are approximated to equivalent square small fields using the definition proposed by Cranmer-Sargison et al. However, the CoP estimates the uncertainties associated with this formula only for rectangular fields with dimensions within the range .
Purpose:
The objective of the present study was to compare the accuracy of the Cranmer-Sargison definition with other formulas for equivalent square small fields in the context of measuring field output factors (FOFs) for rectangular small fields, both within and outside the range covered by the CoP.
Methods:
Measurements were conducted using Gafchromic EBT4 radiochromic films. The models compared included Cranmer-Sargison, Sterling, Superellipse, Sterling-Partial Superellipse, Sterling-Superellipse, Vadash and Bjärngard, and Fogliata. The most accurate definition of equivalent square field size was identified as the one yielding the lowest discrepancy between measured and analytical values, with the log-likelihood of the measurements selected as the metric. Analytical values were derived using the function introduced by Sauer and Wilbert, which relates FOFs to equivalent square field sizes.
Results:
The best results were achieved with the Fogliata model, followed in terms of accuracy by the Sterling-Partial Superellipse model. The Sterling-Superellipse and Vadash and Bjärngard models came next. It should be noted that the Sterling-Partial Superellipse and Sterling-Superellipse models rely solely on the geometric shape of the irradiation field size, whereas the Fogliata and Vadash and Bjärngard models incorporate a fitting parameter. The Sterling definition, while less accurate than these models, improved upon the Cranmer-Sargison definition and retained computational simplicity. Finally, the Cranmer-Sargison and Superellipse models exhibited the largest discrepancies.
Conclusions:
This study identified several definitions of equivalent square small field size that could refine the IAEA TRS-483 CoP by improving the accuracy of field output correction factors for rectangular small fields. Among these definitions, the Fogliata model obtained the best results.
関連する概念動画
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Field Effect Transistor
Electric Field
In the new picture, imagine that the first charge sets up an electric field independent of all other charges in the universe. When another charge comes in its vicinity, the second charge experiences an electric force depending on the electric field at that point. The source charge does not...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Electromagnetic Fields
However, the observation of...
Electric Field Inside a Conductor
Suppose a piece of metal is placed near a positive charge. The free electrons in the metal are attracted to the external positive charge and migrate freely toward that region. This region then...