左室副伝導路アブレーション中の大動脈起始部穿孔に対する多機能閉鎖デバイスを用いた経皮的治療
Rahul Nema1, Ashish Singh1, Rohit Manojkumar1
1Department of Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
Abstract:
Aortic root perforation is a rare but potentially catastrophic complication of transseptal puncture (TSP). We report the case of a 34-year-old male with Wolff-Parkinson-White syndrome who sustained inadvertent aortic root access during an electrophysiologic study and left-sided accessory pathway ablation. The complication led to tamponade and cardiac arrest but was successfully managed percutaneously using a KONAR-Multifunctional occluder device. The patient subsequently underwent successful ablation and had an uneventful recovery. This case highlights key steps for timely recognition, hemodynamic stabilization, and definitive percutaneous closure of aortic perforation. It also provides important technical and anatomical considerations for the safe performance of TSP in electrophysiology.
さらに関連する動画
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022