双相冲击持续时间对不同电极配置和2相容量的除门的影响:通过上限脆弱性测定进行预测
P N Schauerte1, K Ziegert, M Waldmann
1University of Technology, Department of Cardiology and Cardiovascular Surgery, Aachen, Germany. Patrick-Schauerte@ouhsc.edu
Circulation
|March 23, 1999
概括
脆弱性的上限 (ULV) 可以预测除门 (DFT) 波形. 较低的2相电容降低了DFT,无论双相冲击持续时间 (BSD).
科学领域:
- 心血管生理学心血管生理学
- 电力生理学 电力生理学
- 医疗器械工程 医疗器械工程
背景情况:
- 除门 (DFT) 受双相冲击持续时间 (BSD),电极配置和电容的影响.
- 脆弱性的上限 (ULV) 可以作为DFT的估计.
研究的目的:
- 调查ULV是否可以预测具有最低DFT的波形.
- 评估不同配置和第二阶段容量的使用猪ULV对DFT预测的影响.
主要方法:
- 在18头猪中使用上下协议确定了10个BSD的DFT和ULV.
- 通过T波扫描测量ULVs 在心室节拍过程中.
- 使用了两个电极配置 (AC+SVC和AC) 和各种容量 (150μF和300μF).
主要成果:
- 在所有协议中,ULV和DFT显示出显著的线性相关性 (r=0.78到0.84).
- 观察到AC+SVC的最低DFT为10毫秒,AC的最低DFT为14毫秒.
- 降低2期电容降低了DFT,同时增加了最低DFT.
结论:
- 通过ULV测定,可以预测具有最低DFT的波形.
- 最低DFT的最佳BSD在AC+SVC和AC配置之间有所不同.
- 降低2期电容对于降低DFTs是有益的.
相关概念视频
Electrostatic Boundary Conditions in Dielectrics
When an electric field passes from one homogeneous medium to another, crossing the boundary between the two mediums imparts a discontinuity in the electric field. This results in electrostatic boundary conditions that depend on the type of mediums the field propagates through.
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's permittivity.
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's permittivity.
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Mass Analyzers: Common Types
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Tandem Mass Spectrometry
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
Double Resonance Techniques: Overview
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
The Electrical Double Layer
In the region where two bulk phases meet, an intricate electric charge distribution arises due to charge transfer, ion adsorption, molecular orientation, and charge distortion. This complex distribution is commonly referred to as the electrical double layer.When a solid electrode interfaces with ions in an electrolyte solution, the speed of electron transfer dictates the rates of oxidation and reduction. The electrode acquires a charge through the escape of atoms into the solution as cations or...