概括
No abstract available in PubMed .
更多相关视频
05:21Operation of Laboratory Photobioreactors with Online Growth Measurements and Customizable Light Regimes
Published on: October 28, 2021
05:15Inducing the Entry of Third Stage Dispersal Juveniles of Bursaphelenchus xylophilus into Cryptobiosis Through Osmotic Regulation
Published on: December 27, 2024
相关概念视频
Measuring Reaction Rates
Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical field in...
Rise of Liquid in a Capillary Tube
When very thin cylindrical tubes, called capillaries, are dipped in a liquid, the liquid rises or falls in the tube compared to the surrounding liquid. This phenomenon is called capillary action. Capillary action occurs due to the combination of two opposing forces: the cohesive forces of the liquid, which cause it to stick to itself and form a rounded shape, and the adhesive forces between the liquid and the walls of the container, which cause the liquid to be attracted to the container walls.
Glassware Calibration
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Fast Reactions
Fast reactions occurring in times shorter than the time needed to mix reactants pose a unique challenge for investigation. In a liquid-phase continuous-flow system, reactants A and B are swiftly pushed into the mixing chamber, where mixing occurs within 1 ms. The reaction mixture then flows through an observation tube, and one measures light absorption to determine species concentrations at various points of the tube. This method is most appropriate when relatively large volumes of reactants...
