通过含的pi电子系统进行色度计化物离子探测
S Yamaguchi1, S Akiyama, K Tamao
1Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011, Japan.
Journal of the American Chemical Society
|November 15, 2001
概括
新的基化合物作为选择性化物传感器. 它们在化物结合时呈现出明显的颜色变化和光谱变化,使其能够进行敏感的检测.
科学领域:
- 材料科学 材料科学 材料科学
- 分析化学 分析化学
- 有机化学 有机化学
背景情况:
- 含的pi合系统具有独特的电子特性.
- 选择性化学传感器的开发对于检测特定离子至关重要.
研究的目的:
- 调查含的新型pi结合系统作为化物化学传感器.
- 描述这些化合物的传感机制和选择性.
主要方法:
- 合成和特征的三-9-乙烯) (1) 和三10-dimesitylboryl) -9 - - 乙烯) (2).
- 紫外线可见吸收光谱检测复合物与化物离子.
- 具有约束力的研究,以确定对各种离子的选择性和亲和力.
主要成果:
- 化合物1显示出明显的颜色变化 (从色到无色) 和在化物复合时的光谱变化.
- 化物的高结合常数[{2.8 +/- 0.3) x 10{5) M{-1) ]与酸盐和氧化物的亲和力较低.
- 化合物2由于逐步的化物复合而表现出多阶段的光谱变化.
结论:
- 三9-甲基) (1) 作为化离子的选择性和敏感的化学传感器.
- 传感机制包括在化酸盐形成时中断pi-结合.
- 像compound 2这样的多离子系统为复杂的离子传感应用提供了潜力.
相关概念视频
Chemical Ionization (CI) Mass Spectrometry
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
UV–Vis Spectroscopy of Conjugated Systems
Organic compounds with conjugated double bonds show strong absorption features in the UV–visible region of the electromagnetic spectrum attributed to π → π* electronic excitations. Generally, a UV–vis absorption spectrum is recorded as a plot of absorbance vs wavelength. The wavelength of maximum absorbance, which manifests as a peak in the absorption spectrum, is denoted as λmax.
One of the factors influencing λmax is the extent of conjugation in the...
One of the factors influencing λmax is the extent of conjugation in the...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Gas Chromatography: Types of Detectors-II
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Determination of Crystal Structures
In the late 1800s, the revelation that light extended beyond visible wavelengths led to the discovery of X-rays by Wilhelm Roentgen. Recognized as high-energy electromagnetic radiation with short wavelengths, X-rays prompted exploration into their interaction with crystals. Max von Laue proposed in 1912 that the periodic arrangement of atoms, ions, or molecules in crystals would cause them to diffract X-rays, a hypothesis confirmed through experiments with copper sulfate and zinc sulfide...