:,.

N Brose1, A G Petrenko, T C Südhof

  • 1Department of Neurochemistry, Max-Planck-Institute for Psychiatry, Martinsried, Germany.

Science (New York, N.Y.)
|May 15, 1992
PubMed
概括

突触囊泡蛋白质Synaptotagmin结合和负电荷的脂. 这种结合,对于神经递质释放至关重要,取决于synaptotagmin.

相关概念视频

Gap Junctions01:37

Gap Junctions

Multicellular organisms employ a variety of ways for cells to communicate with each other. Gap junctions are specialized proteins that form pores between neighboring cells in animals, connecting the cytoplasm between the two, and allowing for the exchange of molecules and ions. They are found in a wide range of invertebrate and vertebrate species, mediate numerous functions including cell differentiation and development, and are associated with numerous human diseases, including cardiac and...
Ammeter01:11

Ammeter

An ammeter is a current measuring instrument. In the circuit, it is represented by the symbol A. The ammeter is placed in series with the device or component to measure the current. A series connection is used because objects in series have the same current passing through them. If a circuit has multiple resistors and the current needs to be measured in each resistor, the number of ammeters required depends on whether the circuit is in series or parallel.
When an ammeter is used to measure the...
Mutual Inductance01:24

Mutual Inductance

Inductance is the property of a device that tells us how effectively it induces an emf in another device. In other words, it is a physical quantity that expresses the effectiveness of a given device.
When two circuits carrying time-varying currents are close to one another, the magnetic flux through each circuit varies because of the changing current in the other circuit. Consequently, an emf is induced in each circuit by the changing current in the other. Therefore, this type of emf is called...
Instrument Transformers01:23

Instrument Transformers

Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...