Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Impact01:30

Impact

Impact occurs when two bodies collide, leading to the application of impulsive forces between them. Analyzing impact mechanics involves considering two colliding particles moving along a line known as the line of impact, which passes through their centers and is perpendicular to the contact plane.
When particles with different initial velocities collide, they induce deformation by applying equal and opposite impulses. At the point of maximum deformation, the particles move together with...

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Combinatorial decision-making driven by multicomponent surface condensates.

Proceedings of the National Academy of Sciences of the United States of America·2026
Same author

An AI system to help scientists write expert-level empirical software.

Nature·2026
Same author

Fitting coarse-grained models to macroscopic experimental data via automatic differentiation.

Proceedings of the National Academy of Sciences of the United States of America·2026
Same author

Expert evaluation of LLM world models: A high-T<sub><i>c</i></sub> superconductivity case study.

Proceedings of the National Academy of Sciences of the United States of America·2026
Same author

Ion pairing enhances hydroquinone stability toward oxygen in aqueous electrochemical carbon dioxide capture.

Nature communications·2025
Same author

Generalized design of sequence-ensemble-function relationships for intrinsically disordered proteins.

Nature computational science·2025

相关实验视频

Updated: Jun 28, 2026

Characterization of Surface Modifications by White Light Interferometry: Applications in Ion Sputtering, Laser Ablation, and Tribology Experiments
11:47

Characterization of Surface Modifications by White Light Interferometry: Applications in Ion Sputtering, Laser Ablation, and Tribology Experiments

Published on: February 27, 2013

离子喷射中的冲击会使的表面特征变得利.

H Henry Chen1, Omar A Urquidez, Stefan Ichim

  • 1Department of Physics, Harvard University, Cambridge, MA 02138, USA.

Science (New York, N.Y.)
|October 15, 2005
PubMed
概括

离子束喷射在表面上产生通用,稳定的斜率,在不散射特征的情况下传播. 这种冲击前端的行为允许在保持度的同时进行图案缩放.

科学领域:

  • 表面科学是一门科学.
  • 材料科学是一种材料科学.
  • 薄膜的物理学 薄膜的物理学

背景情况:

  • 离子束喷射是表面修饰和纳米制造的关键技术.
  • 了解在离子辐射下表面演变的动态对于控制纳米结构至关重要.
  • 之前的模型往往侧重于更光滑的表面演变,不太关注高斜率的模式.

研究的目的:

  • 为了研究离子束在斜坡的表面喷射的行为.
  • 为了确定是否有一个普遍的制度存在于高斜率的表面演化.
  • 探索这种行为对模式制造和扩展的影响.

主要方法:

  • 离子束喷射动态的理论建模.
  • 在离子辐射下对表面演变的实验研究.
  • 分析斜率传播和特征稳定性的分析.

主要成果:

  • 对于足够的表面斜坡,已经确定了独特的喷模式.
  • 高斜率在很长的距离上传播,而没有显著的特征消散.
  • 传播速度和动态选择的斜率都是普遍的,独立于初始表面地形.

结论:

更多相关视频

Visualization of High Speed Liquid Jet Impaction on a Moving Surface
08:34

Visualization of High Speed Liquid Jet Impaction on a Moving Surface

Published on: April 17, 2015

Electrochemical Etching and Characterization of Sharp Field Emission Points for Electron Impact Ionization
06:58

Electrochemical Etching and Characterization of Sharp Field Emission Points for Electron Impact Ionization

Published on: July 12, 2016

相关实验视频

Last Updated: Jun 28, 2026

Characterization of Surface Modifications by White Light Interferometry: Applications in Ion Sputtering, Laser Ablation, and Tribology Experiments
11:47

Characterization of Surface Modifications by White Light Interferometry: Applications in Ion Sputtering, Laser Ablation, and Tribology Experiments

Published on: February 27, 2013

Visualization of High Speed Liquid Jet Impaction on a Moving Surface
08:34

Visualization of High Speed Liquid Jet Impaction on a Moving Surface

Published on: April 17, 2015

Electrochemical Etching and Characterization of Sharp Field Emission Points for Electron Impact Ionization
06:58

Electrochemical Etching and Characterization of Sharp Field Emission Points for Electron Impact Ionization

Published on: July 12, 2016

  • 观察到的行为类似于冲击阵线的传播,具有自我选择的稳定斜率,类似于薄膜流体流.
  • 实验结果验证了理论预测.
  • 这种现象使得可以制造出大规模的图案,这些图案可以在保持或提高细微特征的同时,均地缩小尺寸.