Electric and Magnetic Field Devices for Stimulation of Biological Tissues
Published on: May 15, 2021
电压激活通道的分单元固态度的确定
1Department of Cellular and Molecular Physiology, Harvard Medical School, Boston, Massachusetts 02115.
Nature
|March 21, 1991
概括
研究人员确定了电压激活 (K+) 通道的结构. 利用子毒素与Shaker K+通道的相互作用,他们发现这些通道具有四重体结构,对于细胞膜中的电信号至关重要.
科学领域:
- 分子生物学分子生物学
- 神经科学是一个神经科学.
- 生物物理学的生物物理.
背景情况:
- 电压激活的离子通道 (K+,Na+,Ca2+) 在细胞膜中产生电信号.
- (K+) 通道是由多个子单元组成的多重蛋白质.
- 在此之前,K+通道的精确体积计子单元是未知的.
研究的目的:
- 为了确定Shaker K+通道的分单元静脉测量.
- 阐明电压激活的K+通道的结构组织.
主要方法:
- 野生类型和对毒素不敏感的突变Shaker K+通道的同时表达.
- 研究子毒素和Shaker K+通道变体之间的相互作用.
主要成果:
- 确定Shaker K+通道具有四重体结构.
- 这一发现与K+通道和Na+和Ca2+通道中的同源重复之间的序列同质性一致.
结论:
- 建立了Shaker K+通道的四重体结构.
- 这种固态度在不同的电压激活离子通道家族中保持,影响电信号传播.
相关概念视频
The Electrical Double Layer
In the region where two bulk phases meet, an intricate electric charge distribution arises due to charge transfer, ion adsorption, molecular orientation, and charge distortion. This complex distribution is commonly referred to as the electrical double layer.When a solid electrode interfaces with ions in an electrolyte solution, the speed of electron transfer dictates the rates of oxidation and reduction. The electrode acquires a charge through the escape of atoms into the solution as cations or...
Insulation Coordination
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times for...
Capacitance: Single-Phase And Three-Phase Line
In electrical power systems, understanding the capacitance of transmission lines is fundamental for efficient operation.
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Control of Power Flow
There are several methods to control power flow in power systems:
Power System Three-Phase Short Circuits
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
Generator Voltage Control
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...