基于加多的混合纳米粒子作为积极的MR对比剂
Hiroki Hifumi1, Seiichi Yamaoka, Akihiro Tanimoto
1Department of Applied Chemistry, Faculty of Science and Technology, Keio University, Kohoku-ku, Yokohama 223-8522, Japan.
Journal of the American Chemical Society
|November 23, 2006
概括
一种新的纳米颗粒对比剂,PGP/dextran-K01被开发出来. 其独特的特性使其成为现有的负对比剂的有希望的临床替代品.
科学领域:
- 纳米医学是一种纳米医学.
- 材料科学 材料科学 材料科学
- 放射学 放射学是指放射学
背景情况:
- 开发先进的对比剂对于改善诊断成像至关重要.
- 现有的阳性对比剂经常面临有效性和安全性的挑战.
- 纳米颗粒剂为增强成像提供了独特的特性.
研究的目的:
- 为了合成和描述一种新的无机有机混合物纳米颗粒正极对比剂.
- 评估新药物的放松性质和潜在的临床实用性.
- 评估开发的对比剂的安全性.
主要方法:
- 合成PGP/dextran-K01使用GdPO4无机核心和德克斯涂层.
- 单分散性,放松时间 (r1,r2) 和r2/r1比率的表征.
- 在体内有毒性研究以评估安全性.
主要成果:
- PGP/dextran-K01在水中表现出单分散性.
- 该药物表现出高的r1和r2值.
- 获得了前所未有的1.1的低r2/r1值,表明了积极的对比性质.
- 在体内研究中观察到毒性降低.
结论:
- PGP/dextran-K01是一种具有卓越放松性质的新型阳性对比剂.
- 它的低r2/r1值和纳米颗粒性质表明它是负对比剂的潜在临床替代品.
- 该药物显示为增强诊断成像和提高安全性的有前途.
相关概念视频
¹³C NMR: ¹H–¹³C Decoupling
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
Chemical Shift: Internal References and Solvent Effects
In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Double Resonance Techniques: Overview
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...