概括
这项研究使用微红外光谱学量化MgSiO(3) 矿中的微量. 这些发现表明,地球下层地幔中存在大量的气,与水球相似.
科学领域:
- 地质化学 地质化学
- 矿物物理 矿物物理
- 频谱学是一种光谱学.
背景情况:
- MgSiO(3) 矿是地球下层地幔中的主要矿物.
- 了解其微量元素含量,特别是,对于地幔的组成和动态至关重要.
- 名义上无水矿物质可以含有大量的.
研究的目的:
- 测量MgSiO的单晶中的微量含量.
- 为了研究这个地幔矿物中的分布和度.
- 为了将估计的下层地幔含量与地球水球进行比较.
主要方法:
- 使用微红外光谱学与同步红外光源.
- 分析了3483和3423厘米的吸收峰值,以确定氧化物存在.
- 基于光谱学数据的量化度.
主要成果:
- 在MgSiO(3) 矿中确定了两个明显的粉氧化吸收峰值.
- 确定的微量含量为700 +/- 170个原子,每10 (六) 个Si原子.
- 计算出这种度,集成在下层地幔上,大约是地球水球质量的12%.
结论:
- 矿含有可测量的和大量的微量.
- 下层地幔可能含有大量的气储备,影响地幔的性质.
- 这些发现需要重新评估地球内的水含量和循环.
相关概念视频
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
A covalently bonded heteronuclear diatomic molecule can be modeled as two vibrating masses connected by a spring. The vibrational frequency of the bond can be expressed using an equation derived from Hooke's law, which describes how the force applied to stretch or compress a spring is proportional to the displacement of the spring. In this case, the atoms behave like masses, and the bond acts like a spring.
According to Hooke's law, the vibrational frequency is directly proportional to the...
According to Hooke's law, the vibrational frequency is directly proportional to the...
IR Absorption Frequency: Hybridization
Hydrocarbons such as alkanes, alkenes, and alkynes show characteristic C–H stretching absorption bands. These IR stretching frequencies depend on the hybridization of the involved carbon atom and can be explained in terms of the s character of each hybridized atomic orbital.
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
IR Spectrum Peak Broadening: Hydrogen Bonding
The vibrational frequency of a bond is directly proportional to its bond strength. As a result, stronger bonds vibrate at higher frequencies, while weaker bonds vibrate at lower frequencies. The stretching vibration of the strong O–H bond in alcohols and phenols (very dilute solution or gas phase) appears as a sharp peak at 3600–3650 cm−1.
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular hydrogen bonding...
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular hydrogen bonding...
Infrared (IR) Spectroscopy: Overview
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
UV–Vis Spectroscopy of Conjugated Systems
Organic compounds with conjugated double bonds show strong absorption features in the UV–visible region of the electromagnetic spectrum attributed to π → π* electronic excitations. Generally, a UV–vis absorption spectrum is recorded as a plot of absorbance vs wavelength. The wavelength of maximum absorbance, which manifests as a peak in the absorption spectrum, is denoted as λmax.
One of the factors influencing λmax is the extent of conjugation in the...
One of the factors influencing λmax is the extent of conjugation in the...
Atomic Absorption Spectroscopy: Instrumentation
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...