概括
太阳能光伏发电将取代基负荷和中间发电厂. 然而,长期来看,它不会显著节省燃料油,甚至会增加工厂的峰值需求,即使是储存.
科学领域:
- 能源系统分析 能源系统分析
- 整合可再生能源的整合
- 发电经济学 发电经济学
背景情况:
- 公用事业公司面临长期发电需求.
- 太阳能光伏 (PV) 电力是一个不断增长的能源.
- 了解光伏集成对电网的影响至关重要.
研究的目的:
- 分析太阳能光伏发电对电力发电的长期影响.
- 评估燃油节约和峰值工厂要求与光伏集成.
- 为了评估带有和没有储能的光伏性能.
主要方法:
- 对代表性公用事业公司长期发电需求的分析.
- 在适度水平 (峰值负载的几个百分比) 上建模光伏透率.
- 模拟公用事业容量和燃油节省,有或没有负载等级存储.
主要成果:
- 光伏能源主要取代基负荷和中间发电厂.
- 由于公用事业公司优化发电组合,长期显著的燃油节省不太可能.
- 太阳能光伏集成可能会增加峰值工厂的需求,即使是储存.
结论:
- 太阳能发电的主要作用是取代传统的基负荷和中间发电.
- 经济最佳情况表明,光伏的长期燃油节约有限.
- 光伏的电网集成需要仔细考虑峰值负载管理和存储解决方案.
相关概念视频
Secondary Distribution
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
The Power Flow Problem and Solution
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the power flow program computes the...
P-N junction
A p-n junction is formed when p-type and n-type semiconductor materials are joined together. At the interface of the p-n junction, holes from the p-side and electrons from the n-side begin to diffuse into the opposite sides due to the concentration gradient. This diffusion of carriers leads to a region around the junction where there are no free charge carriers, known as the depletion region. The charge density within the depletion region for the n-side and p-side can be described by the...
Maximum Power Flow and Line Loadability
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
Fast Decoupled and DC Powerflow
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
Power System Distribution
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...