Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers
Published on: August 18, 2017
概括
一种新技术通过利用电子剥离后的核库伦反射来提供分子的直接几何图像. 这种方法已经产生了关键物种 (如甲离子) 的结构图像.
科学领域:
- 物理化学 物理化学
- 分子成像学分子成像学
- 频谱学是一种光谱学.
背景情况:
- 传统的分子结构确定依赖于间接方法,分析质谱等属性.
- 对分子几何学的直接可视化一直是化学的一个长期挑战.
研究的目的:
- 介绍和演示一种用于获得单个分子直接几何图像的新方法.
- 展示这种新技术在分子结构阐明方面的能力.
主要方法:
- 在分子中原子核之间利用库伦反射,迅速剥夺了它们的电子.
- 开发和应用一种技术,从这种排斥现象中捕获和重建分子图像.
主要成果:
- 成功生成了单个分子的直接几何图像.
- 获得了重要的化学物种的结构图像,包括带正电荷的甲离子.
结论:
- 新方法为分子结构成像提供了直接途径,补充了现有的间接技术.
- 这种技术有望促进对分子结构和动态的理解.
相关概念视频
Electron Microscope Tomography and Single-particle Reconstruction
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Atomic Emission Spectroscopy: Lab
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
π Electron Effects on Chemical Shift: Overview
An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0, resulting in...
Atomic Fluorescence Spectroscopy
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which are...
Chemical Ionization (CI) Mass Spectrometry
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.