相关实验视频
Updated: Jul 12, 2026

09:33
An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
概括
一个新的原子吸收光谱仪可以持续监测环境空气中的总. 这种敏感的设备检测到0.2μg/m3的,符合空气质量建议的联邦指南.
科学领域:
- 环境科学 环境科学
- 分析化学 分析化学
- 频谱学是一种光谱学.
背景情况:
- 是一种有毒的污染物,具有重大环境和健康影响.
- 持续监测环境空气中的对于评估暴露风险至关重要.
- 现有的方法往往缺乏对总的实时分析的灵敏度或能力.
研究的目的:
- 展示一种用于环境空气中持续监测的新型原子吸收光谱仪.
- 评估开发的仪器的灵敏度和检测极限.
- 评估其检测蒸气和颗粒的能力.
主要方法:
- 使用同位素转移,泽曼效应原子吸收光谱仪.
- 使用仪器持续监测环境空气中的总.
- 确定了的最小可检测度.
主要成果:
- 开发的光谱仪显示出足够的灵敏度用于持续监测.
- 最低可检测的总度为0.2微克/立方米空气.
- 这个检测极限是拟议的联邦指南的五分之一.
结论:
- 同位素转移,泽曼效应原子吸收光谱仪是持续环境空气监测的可行工具.
- 该仪器具有高灵敏度,能够检测低于拟议的联邦指南水平的.
- 这代表了实时气质量评估的重大进步.
相关概念视频
Gas Chromatography: Types of Detectors-II
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Gas pressure is caused by force exerted by gas molecules colliding with the surfaces of objects. Although the force of each collision is very small, any surface of an appreciable area experiences a large number of collisions in a short time, which can result in high pressure.
Equipments Used to Measure Body Temperature
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...