相关实验视频
Updated: Jul 11, 2026

10:26
Fabrication and Characterization of Superconducting Resonators
Published on: May 21, 2016
概括
新的低温重力辐射探测器几乎已经准备好了,通过冷学和仪器仪表的创新来实现高灵敏度. 对共振质量探测器的进一步改进是可能的,接近量子极限.
科学领域:
- 物理 物理学 物理
- 天体物理学 天体物理学
- 仪器化 仪器化 仪器化
背景情况:
- 重力波探测对于理解宇宙事件至关重要.
- 以前的探测器在灵敏度和降噪方面遇到了局限性.
研究的目的:
- 报告第二代低温重力辐射探测器网络的发展情况.
- 突出技术进步,使探测器灵敏度提高.
主要方法:
- 利用先进的冷学来实现低温操作.
- 使用低噪音的超导仪器仪表.
- 实施复杂的振动隔离技术.
主要成果:
- 第二代探测器即将完成,其对机械应变的灵敏度为10~18.
- 技术创新显著提高了探测器的性能.
结论:
- 开发的网络代表了引力波检测能力的重大进步.
- 从理论上讲,在探测器能量灵敏度上进一步大幅度改进是可能的.
更多相关视频
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
12:21Stimulated Stokes and Antistokes Raman Scattering in Microspherical Whispering Gallery Mode Resonators
Published on: April 4, 2016
相关概念视频
High-Resolution Mass Spectrometry (HRMS)
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...
Mass Analyzers: Common Types
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Detection of Black Holes
Although black holes were theoretically postulated in the 1920s, they remained outside the domain of observational astronomy until the 1970s.
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
High-Performance Liquid Chromatography: Types of Detectors
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Mass Spectrometers
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions: