相关实验视频
Updated: Jul 3, 2026

11:34
Scattering And Absorption of Light in Planetary Regoliths
Published on: July 1, 2019
水星上的反射和颜色变化: regolith过程和组成异质性
Mark S Robinson1, Scott L Murchie, David T Blewett
1School of Earth and Space Exploration, Arizona State University, Tempe, AZ 85287, USA. robinson@ser.asu.edu
概括
探测器MESSENGER的多光谱图像显示了水星.
科学领域:
- 行星科学 行星科学
- 遥感 遥感 遥感 遥感
- 水星地质地质学
背景情况:
- 水星表面的整体反射率很低.
- 之前的研究发现了广泛的光谱变化.
研究的目的:
- 使用多光谱成像来描述水星的表面单位.
- 根据光谱特性识别不同的地质材料.
主要方法:
- 来自MESSENGER航天器 (0.41.0微米) 的多光谱图像的分析.
- 基于反射率和光谱斜率的表面单位的分类.
主要成果:
- 确定了三个大型单位:高反射光滑平原 (火山),低反射材料 (不透明矿物质) 和中间地形 (上层地).
- 不同的单位包括新鲜的火山口喷射物,火山口地板沉积物和无边框沉材料.
结论:
- 水星的表面组成是多样化的,有着与地质过程相关的独特单位.
- 光谱分析提供了对地组成和火山历史的洞察.
相关概念视频
Scanning Electron Microscopy
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
Emission Spectra
When solids, liquids, or condensed gases are heated sufficiently, they radiate some of the excess energy as light. Photons produced in this manner have a range of energies, and thereby produce a continuous spectrum in which an unbroken series of wavelengths is present.
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Microbes and Other Elemental Cycles
Microbial activity plays a pivotal role in the biogeochemical cycling of iron and manganese, especially at the redox gradients characteristic of stratified aquatic environments. These cycles are driven by microbial transformations between oxidized and reduced forms of the metals, allowing organisms to exploit them for metabolic energy and structural purposes.Iron Cycling Across Redox GradientsIn neutral, oxygen-rich surface waters, iron is predominantly found in its oxidized, insoluble ferric...
Gravimetry: Inorganic And Organic Precipitating Agents
In gravimetry, the precipitant is chosen carefully to obtain a pure solid that can be easily filtered. Common inorganic precipitants can be used to determine several cations and anions. In some cases, the formation of the same precipitate can be used to determine the cation and the anion. For example, the reaction of barium and chromate ions to give barium chromate is used to determine both barium and chromate. However, precipitates such as hydroxides, oxalates, and metal ammonium phosphates...
Total Internal Reflection Fluorescence Microscopy
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
