电功能的八极 π 结合柱状液晶.
Takuma Yasuda1, Tomohiro Shimizu, Feng Liu
1Department of Chemistry and Biotechnology, School of Engineering, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
Journal of the American Chemical Society
|July 28, 2011
概括
新的螺旋形分子在液晶中表现出双极电荷传输. 这些八极结构自组织成纳米结构,以提供高效的孔和电子导电.
科学领域:
- 材料科学 材料科学 材料科学
- 有机电子 有机电子
- 超分子化学 超分子化学
背景情况:
- 对于先进的电子设备来说,开发具有双极电荷传输特性的有机材料至关重要.
- 八极 π 结合分子具有独特的自我组装和电子特性.
- 液晶材料提供有序的结构,以有效地传输电荷.
研究的目的:
- 设计和合成新的螺旋形 π 结合分子用于双极电荷传输液晶应用.
- 为了研究这些八极分子的自我组装行为和电荷传输特性.
- 建立一种多功能方法,用于创建具有可调节电子特性的1D纳米结构材料.
主要方法:
- 基于2,4,6-tris ((thiophene-2-yl) -1,3,5-triazine的螺旋分子的合成.
- 测量飞行时间以确定载体的机动性.
- 循环电压测量和理论计算来分析电子结构.
主要成果:
- 成功合成了螺旋形的八极分子,具有电子捐赠和电子接受部分.
- 观察到自我组织成一维的柱状纳米结构.
- 证明了双极载体运输行为,促进了孔和电子导电.
结论:
- 设计的八极分子自组装成有序的1D纳米结构,使两极电荷传输.
- 这项工作为开发先进的双极导电液晶材料提供了新的策略.
- 这些发现为未来的有机电子分子设计提供了指导方针.
相关概念视频
Ion Exchange
Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or basic...
Ion-Exchange Chromatography
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
High-Performance Liquid Chromatography: Introduction
High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
In HPLC, two phases play a critical role in the separation process:
Principles Of Column Chromatography
The chromatography technique was first invented in 1901 by Michael S. Tswett, a Russian botanist, to separate plant pigments using organic solvents. Further, in 1941, Archer John Porter Martin and R. L. M. Synge modified the technique by packing silica gel into a column. A mixture of amino acids was then separated on the packed column using chloroform and water mixture as the mobile phase. This was the first report on column chromatography. At present, column chromatography is a widely used...
Supercritical Fluid Chromatography
Supercritical fluid chromatography (SFC) provides a beneficial substitute for gas chromatography (GC) and liquid chromatography (LC) for certain samples because it merges the top attributes of both techniques. SFC allows the separation and analysis of compounds that GC or LC does not easily manage. These compounds are traditionally nonvolatile or thermally unstable, making GC unsuitable and lacking functional groups required for HPLC analysis.
SFC utilizes a supercritical fluid mobile phase,...
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Types of Columns and Stationary Phases
Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...