通过质谱测量探测键能量
Hai-Feng Su1, Lan Xue, Yun-Hua Li
1State Key Laboratory for Physical Chemistry of Solid Surfaces and Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
Journal of the American Chemical Society
|April 5, 2013
概括
使用脱电喷电离 (DESI) 的质谱有效测量固态复合体中的键强度. 这种方法为分析这些关键的分子相互作用提供了传统技术的多功能替代方案.
科学领域:
- 分析化学 分析化学
- 物理化学 物理化学
- 频谱学是一种光谱学.
背景情况:
- 结合在分子相互作用和材料特性中起着至关重要的作用.
- 量化键强度对于理解化学和生物系统至关重要.
- 像X射线衍射这样的现有方法在直接探测键能量方面存在局限性.
研究的目的:
- 为了证明大质谱仪的实用性,使用脱电喷射电离 (DESI) 来探测键强度.
- 在固态复合体中建立碎片化效率和键能量之间的相关性.
- 提出一种机制,用质谱测量来确定键特性.
主要方法:
- 使用脱电喷射电离 (DESI) 质谱法.
- 使用碰撞诱导解离 (CID) 来分解分子复合体.
- 分析碎片化效率并将其与键特性相关联.
- 进行复合物混合和标签的实验.
主要成果:
- 通过DESI质谱仪,成功探测了西和碳酸复合物的键强度.
- 通过CID获得的碎片化效率与键能量 (O-H··N和N-H··O) 相对相关.
- 在碎片化参数和键特性 (长度和长度差异) 之间建立了线性相关性.
结论:
- DESI质谱仪提供了一种多功能且有效的方法来量化固态中的键能量.
- 拟议的质谱方法补充了现有的技术,如X射线衍射.
- 这种方法有望在研究分子相互作用方面得到更广泛的应用.
相关概念视频
Mass Spectrometry: Complex Analysis
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Overview
Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electron ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave behind a...
High-Resolution Mass Spectrometry (HRMS)
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...
IR Spectrum Peak Broadening: Hydrogen Bonding
The vibrational frequency of a bond is directly proportional to its bond strength. As a result, stronger bonds vibrate at higher frequencies, while weaker bonds vibrate at lower frequencies. The stretching vibration of the strong O–H bond in alcohols and phenols (very dilute solution or gas phase) appears as a sharp peak at 3600–3650 cm−1.
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular hydrogen bonding...
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular hydrogen bonding...
Mass Spectrum: Interpretation
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Mass Spectrum
A mass spectrum is the graphical representation of the relative abundance of the charged fragments in an analyte plotted against their mass-to-charge ratio (m/z). The plot's x-axis represents the ratio of the mass of the charged fragment to the number of charges it carries. The y axis of the plot represents the relative abundance of each charged species. The relative abundance is calculated from the signal intensity of each charged species recorded at the detector. The most intense signal (the...