通过静电相互作用与多糖的金属循环及其用于氨酸检测的等级自组
Li-Jun Chen1, Yuan-Yuan Ren1, Nai-Wei Wu1
1Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, East China Normal University , Shanghai 200062, PR China.
Journal of the American Chemical Society
|September 1, 2015
概括
这项研究首次证明了带正电荷的有机 (II) 金属循环与负电荷的肝素的等级自组. 这一过程产生了纠的网络,并使得敏感的,选择性的光检测能够检测出肝素.
科学领域:
- 超分子化学
- 材料科学
- 协调化学
背景情况:
- 在创建先进的功能性材料时, 层次的自我组装至关重要.
- 离散的金属循环作为超分子结构的多功能支架.
- 静电相互作用可以驱动充电分子的自我组装.
研究的目的:
- 报告由静电相互作用引起的离散金属自组合的第一个实例.
- 引入聚合诱导排放 (AIE) 活性部分用于监测自组装.
- 开发一种敏感和选择性的光探针来检测肝素.
主要方法:
- 有机 (II) 金属循环的协调自组装.
- 引入四乙烯 (TPE) 用于聚合诱导的排放.
- 使用肝素作为负电荷的诱导剂进行静电自组.
- 使用SEM,TEM,AFM和LSCM进行表征.
主要成果:
- 通过静电相互作用与负电荷的肝素自组装的正电荷TPE金属循环.
- 通过显微镜证实了这种情况.
- 光增强表明成功聚合并提供"启动"反应.
- 该系统在检测肝素方面表现出高度的灵敏性和选择性.
结论:
- 这项研究提出了一种用于对抗聚离子诱导的金属自组的新方法.
- 开发的TPE金属循环系统可以作为有效的光探针来检测肝素.
- 这项研究为涉及肝素的传感和结合应用提供了原则证明.
相关概念视频
Potentiometry: Types of Electrodes
2.5K
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
2.5K
Potentiometry: Membrane Electrodes
2.3K
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.3K
Amperometry: Overview
2.2K
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
2.2K
Precipitation and Co-precipitation
4.9K
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
4.9K
Electrodeposition
2.7K
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...
2.7K
High-Performance Liquid Chromatography: Types of Detectors
2.3K
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
2.3K


