在Drosophila的中央电路中触觉信号的并行转换
John C Tuthill1, Rachel I Wilson1
1Department of Neurobiology, Harvard Medical School, 220 Longwood Avenue, Boston, MA 02115, USA.
Cell
|February 27, 2016
概括
这项研究揭示了果 (Drosophila) 如何使用中央神经元的并行处理来整合触摸信号. 这种并行比较系统有效地传输运动控制的体感信息.
科学领域:
- 神经科学
- 感官生物学
- 昆虫生理学
背景情况:
- 复杂的体感知需要整合来自各种外周机理受体和身体位置的信号.
- 了解体感集成的初始阶段对于破译触觉神经处理至关重要.
研究的目的:
- 研究Drosophila中枢神经系统中体感集成的早期机制.
- 确定参与处理触摸刺激的中枢神经元类别及其功能作用.
主要方法:
- 使用基因标记的Drosophila中央神经元的体内记录.
- 使用特定机械受体类型的机械和光遗传刺激.
- 分析神经对体感处理路径的反应.
主要成果:
- 确定了三种不同类型的中央神经元处理触摸信息.
- 发现神经元比较肢体内的触觉信号,肢体之间的触觉,以及触觉与自身感知.
- 证明了个体触摸受体轴突分离到三种神经元类别并行.
结论:
- 在Drosophila中,体感集成涉及并行处理流而不是严格的层次结构.
- 这种并行比较策略使体感数据能够快速有效地传输到电机电路.
- 这些发现提供了神经系统感官信息处理的基本原理.
更多相关视频
05:48A Behavioral Assay for Mechanosensation of MARCM-based Clones in Drosophila melanogaster
Published on: December 30, 2015
10.7K
11:42Electrophysiological Method for Recording Intracellular Voltage Responses of Drosophila Photoreceptors and Interneurons to Light Stimuli In Vivo
Published on: June 19, 2016
20.2K
相关概念视频
The Y-to-Delta Circuit
A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
The Delta-to-Delta Circuit
In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
Multi-input and Multi-variable systems
Cruise control systems in cars are designed as multi-input systems to maintain a driver's desired speed while compensating for external disturbances such as changes in terrain. The block diagram for a cruise control system typically includes two main inputs: the desired speed set by the driver and any external disturbances, such as the incline of the road. By adjusting the engine throttle, the system maintains the vehicle's speed as close to the desired value as possible.
In the absence of...
In the absence of...
Signal Flow Graphs
Signal-flow graphs offer a streamlined and intuitive approach to representing control systems, providing an alternative to traditional block diagrams. These graphs use branches to symbolize systems and nodes to represent signals, effectively illustrating the relationships and interactions within the system.
In a signal-flow graph, branches denote the system's transfer functions, while nodes represent the signals. The direction of signal flow is indicated by arrows, with the corresponding...
In a signal-flow graph, branches denote the system's transfer functions, while nodes represent the signals. The direction of signal flow is indicated by arrows, with the corresponding...
Directional Relays
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
Differential Relays
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...