用于测量合体光ZnO纳米晶体的电位定位
Carl K Brozek1, Kimberly H Hartstein1, Daniel R Gamelin1
1Department of Chemistry, University of Washington , Seattle, Washington 98195-1700, United States.
Journal of the American Chemical Society
|July 23, 2016
概括
电位计定量ZnO纳米晶体的氧化还原特性. 这种方法揭示了费米水平和充电潜力,为研究体半导体提供了一种新方法.
科学领域:
- * 材料科学
- * 电化学
- * 纳米技术
背景情况:
- * 体半导体纳米晶体对于弥合分子和散装半导体氧化还原现象至关重要.
- 了解它们的氧化还原特性是开发新电子和光电子应用的关键.
研究的目的:
- * 证明电位定位是一种用于量化合半导体纳米晶体的新方法.
- * 确定n型ZnO纳米晶体的费米水平和充电潜力.
- * 调查纳米晶体大小和对抗作用对这些特性的影响.
主要方法:
- * 用电位计计量来测量 ZnO 纳米晶体的费米水平和充电潜力.
- * 该技术应用于具有不同电子密度的独立体n型ZnO纳米晶体.
- * 分析重点是费米水平,电荷载体密度,纳米晶体大小和反电离性标识之间的关系.
主要成果:
- * 电位计定位成功量化了 ZnO 纳米晶体的费米水平和充电电位 (0-20 导电带电子/纳米晶体).
- * 观察到费米水平和电荷载体密度之间的线性相关性,其倾斜度取决于尺寸.
- * 纳米晶体容量由经典的电双层控制,缺乏量子贡献.
- * 反应标识系统地影响了费米水平的变化.
结论:
- *电位计定位是一种可行且强大的新方法,用于表征体半导体纳米晶体.
- 这项研究提供了这些纳米材料的经典电气双层行为.
- * 这些发现为传统的薄膜电压测量技术提供了无接触的替代方法.
相关概念视频
Potentiometric Titration: Overview
5.2K
Potentiometric titration is a quantitative analytical technique that determines the concentration of an analyte by measuring the potential difference between the two electrodes in the solution. The endpoint of a potentiometric titration is the point at which there is a significant change in the potential difference. It occurs when the stoichiometric reaction between the analyte and the titrant is complete. The endpoint is usually determined graphically by plotting the measured potential...
5.2K
Potentiometry: Overview
5.3K
Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as...
5.3K
Precipitation Titration: Endpoint Detection Methods
6.3K
In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
In the Volhard method, a standard excess of AgNO3 is first added to the...
6.3K
Controlled-Potential Coulometry: Electrolytic Methods
816
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
The chosen potential...
816
Controlled-Current Coulometry: Coulometric Titration
659
Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
659
Complexometric Titration: Overview
12.8K
Complexometric titration involves the formation of a complex by reacting a metal ion with one or more ligands. A visual indicator often detects the end point of a complexometric titration. It is added to the metal solution before the titration, forming a stable metal–indicator complex and imparting color to the solution. As the titration approaches the equivalence point, the excess of the added ligand displaces the indicator from the metal–indicator complex, releasing the free...
12.8K


