高灵敏的连贯抗冲击蛋白质晶体的拉曼散射成像
Grigory M Arzumanyan1,2, Nelya V Doroshkevich1, Kahramon Z Mamatkulov1
1Joint Institute for Nuclear Research , 141980 Dubna, Russia.
Journal of the American Chemical Society
|September 17, 2016
概括
拍摄微小的蛋白质晶体, 尤其是膜蛋白, 是很困难的. 这项研究引入了一种使用连贯反斯托克斯拉曼散射来成像这些具有挑战性的样本的新,高度敏感的方法.
科学领域:
- 结构生物学
- 生物物理
- 晶体学
背景情况:
- 先进的X射线来源使小晶体的连续晶体学成为可能.
- 摄影微米蛋白质晶体,特别是膜蛋白质,仍然是一个重大挑战.
研究的目的:
- 开发和介绍一种新的,高度灵敏的蛋白质晶体成像方法.
- 为了解决成像小和膜蛋白质晶体的局限性.
主要方法:
- 使用连贯的反斯托克斯拉曼散射显微镜 (CARS).
- 应用CARS技术对蛋白质晶体结构进行成像.
主要成果:
- 展示了一种新的,极其灵敏的蛋白质晶体成像方法.
- 成功成像了小的和潜在的膜蛋白晶体.
结论:
- 一致的反斯托克斯拉曼散射为具有挑战性的蛋白质晶体提供了一个有前途的解决方案.
- 这种技术提高了结构生物学分析小晶体样本的能力.
相关概念视频
X-ray Diffraction of Biological Samples
5.1K
X-ray diffraction or XRD is an analytical tool that utilizes X-rays to study ordered structures such as crystalline organic and inorganic samples, polycrystalline materials, proteins, carbohydrates, and drugs.
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
5.1K
Raman Spectroscopy Instrumentation: Overview
1.6K
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.6K
Raman Spectroscopy: Overview
2.2K
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
2.2K
X-ray Crystallography
26.6K
The size of the unit cell and the arrangement of atoms in a crystal may be determined from measurements of the diffraction of X-rays by the crystal, termed X-ray crystallography.
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
26.6K
Cryo-electron Microscopy
4.5K
Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
4.5K
Total Internal Reflection Fluorescence Microscopy
13.6K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
13.6K


