对Kondo共振的冷电荷的观察
相关实验视频
Updated: May 2, 2026

10:26
Fabrication and Characterization of Superconducting Resonators
Published on: May 21, 2016
11.2K
M M Desjardins1, J J Viennot2, M C Dartiailh1
1Laboratoire Pierre Aigrain, Ecole Normale Supérieure-PSL Research University, CNRS, Université Pierre et Marie Curie-Sorbonne Universités, Université Paris Diderot-Sorbonne Paris Cité, 24 rue Lhomond, 75231 Paris Cedex 05, France.
Nature
|April 14, 2017
概括
研究人员使用电路量子电动学研究了量子点电路中的孔多效应. 他们揭示了电荷动力学如何使电荷被库伦相互作用结时也能进行导电.
科学领域:
- 凝聚物质物理学
- 量子信息科学
- 纳米电子
背景情况:
- 量子点电路是理解强大的电子相关性的关键.
- 孔多效应是凝聚物质中的多体现象的一个典型例子.
- 控制纳米电子状态对于现代物理学来说至关重要.
研究的目的:
- 通过电路量子电动学来研究孔多效应的内部自由度.
- 直接测量Kondo模式中的电子转移的电荷动态.
- 在多体系统中区分电子压缩性和导电性.
主要方法:
- 连接一个量子点到一个高质量的微波腔.
- 同时进行电子压缩性和导电性测量.
- 使用电路量子电动学架构进行敏感测量.
主要成果:
- 电子压缩性是非常灵敏的测量.
- 康多共振被观察到对微波光子是透明的.
- 有限导电是由库伦相互作用结的电荷引起的,与自由电子气体的行为形成鲜明对比.
结论:
- 双重测量揭示了控制康多效应的电荷动态.
- 腔量子电动力学为具有多体相关性的中距离电路提供了敏感的探测器.
- 这项工作提供了用于量子模拟费米子-玻色子问题的模型系统.
相关概念视频
Atomic Nuclei: Larmor Precession Frequency
3.5K
The earth's gravitational field produces a 'twisting force' perpendicular to the angular momentum of a spinning mass (such as a spinning top) that causes the mass to 'wobble' around the gravitational field axis in a phenomenon called precession. Similarly, the magnetic moment (μ) of a spinning nucleus precesses due to an external magnetic field directed along the z-axis. The precession of the magnetic moment vector about the magnetic field is called Larmor precession,...
3.5K
Atomic Nuclei: Magnetic Resonance
1.2K
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Atomic Force Microscopy
3.1K
Atomic force microscopy (AFM) is a type of scanning probe microscopy that can analyze topographic details of various specimens like ceramics, glass, polymers, and biological samples. AFM offers over 1000 times more resolution than the optical imaging system. Images generated from AFM are three-dimensional surface profiles, offering an advantage over the flat, two-dimensional images from other imaging techniques.
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
3.1K
Energy Stored In A Coaxial Cable
2.1K
A coaxial cable consists of a central copper conductor used for transmitting signals, followed by an insulator shield, a metallic braided mesh that prevents signal interference, and a plastic layer that encases the entire assembly.
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field...
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field...
2.1K
Magnetic Damping
1.3K
Eddy currents can produce significant drag on motion, called magnetic damping. For instance, when a metallic pendulum bob swings between the poles of a strong magnet, significant drag acts on the bob as it enters and leaves the field, quickly damping the motion.
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
1.3K
Double Resonance Techniques: Overview
870
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
870