使用自由运行的半导体磁盘激光器对水蒸气进行双光谱
S M Link1, D J H C Maas2, D Waldburger3
1Department of Physics, Institute for Quantum Electronics, ETH-Zürich, 8093 Zürich, Switzerland. slink@phys.ethz.ch.
概括
使用单个激光的简化双光谱可以实现高精度和快速的水蒸气测量. 这一突破减少了系统的复杂性,为更广泛的工业应用铺平了道路.
科学领域:
- 光谱学
- 激光物理
- 物理化学
背景情况:
- 双光谱技术提供了高精度和快速的数据采集.
- 目前的系统通常受到光学复杂性的限制.
研究的目的:
- 为水蒸气分析提供简化的双光谱系统.
- 为了减少光学系统的复杂性.
主要方法:
- 使用单激光,自由运行的双模式锁定的半导体光盘激光器.
- 在自由运行和微波稳定运行期间,光模式的绝对稳定性.
主要成果:
- 实现了高精度光谱测量,并快速采样水蒸气.
- 在双光谱学中显著降低了系统复杂性.
结论:
- 简化的单激光方法显著降低了双光谱的复杂性.
- 波段间隙工程可以优化频率对各种工业气体的目标.
相关概念视频
Raman Spectroscopy Instrumentation: Overview
1.5K
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.5K
UV–Vis Spectroscopy: Molecular Electronic Transitions
3.2K
In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
3.2K
Atomic Absorption Spectroscopy: Atomization Methods
1.7K
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
1.7K
Atomic Absorption Spectroscopy: Instrumentation
1.9K
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
1.9K
UV–Vis Spectroscopy: Beer–Lambert Law
7.5K
The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...
7.5K
Molecular Spectroscopy: Absorption and Emission
5.0K
Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels. Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
5.0K