相关实验视频
Updated: Feb 15, 2026

09:30
Bacterial Detection & Identification Using Electrochemical Sensors
Published on: April 23, 2013
29.0K
可光激活的传感器用于检测移动
Jacob M Goldberg1, Fang Wang1, Chanan D Sessler1
1Department of Chemistry, Massachusetts Institute of Technology , 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States.
Journal of the American Chemical Society
|February 1, 2018
概括
研究人员开发了可光激活的光光传感器. 这些新型探测器在生物成像中对检测提供时间控制,增强活细胞和组织中的测量时间分辨率.
科学领域:
- 生物化学 生物化学
- 细胞生物学 细胞生物学
- 化学生物学 化学生物学
背景情况:
- 光传感器对于在生物系统中检测移动至关重要.
- 目前的传感器缺乏时间控制,限制了它们在动态研究中的使用.
- 在体内控制探头活动对于高分辨率成像至关重要.
研究的目的:
- 开发具有时间控制的可光激活光传感器.
- 为了使探头能够使用紫外线激活.
- 为了提高活生物样本中测量的时间分辨率.
主要方法:
- 功能化现有的传感器与光性保护组.
- 使用紫外线光脉冲来触发探头的解除保护和激活.
- 观察活细胞和组织对的反应中的光变化.
主要成果:
- 成功创建了可光激活的传感器.
- 证明了紫外线触发的结合部位的恢复.
- 在活生物系统中观察到可控制的,对有反应的光.
结论:
- 可光激活的传感器提供了前所未有的时间控制.
- 这些探头显著提高了体内成像的时间分辨率.
- 该技术为研究生物动态提供了一个强大的新工具.
相关概念视频
Detection of Gross Error: The Q Test
7.1K
When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
7.1K
Detection of Black Holes
2.6K
Although black holes were theoretically postulated in the 1920s, they remained outside the domain of observational astronomy until the 1970s.
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
2.6K
Difference from Background: Limit of Detection
8.5K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
The LOD indicates the presence or absence...
8.5K
Effects of EDTA on End-Point Detection Methods
669
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
669
Types of Errors: Detection and Minimization
11.5K
Error is the deviation of the obtained result from the true, expected value or the estimated central value. Errors are expressed in absolute or relative terms.
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
11.5K
Precipitation Titration: Endpoint Detection Methods
6.1K
In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
In the Volhard method, a standard excess of AgNO3 is first added to the...
6.1K