用于在延长的时间尺度和区域内高空间和时间分辨率成像活细胞膜动态的活性探针
Huaimin Wang1, Zhaoqianqi Feng1, Steven J Del Signore2
1Department of Chemistry , Brandeis University , 415 South Street , Waltham , Massachusetts 02453 , United States.
Journal of the American Chemical Society
|February 27, 2018
概括
研究人员开发了新的酶反应探针,用于直接对活细胞膜动态进行成像. 这些探测器提供高分辨率,并允许监测膜异质性和外体释放.
科学领域:
- 细胞生物学
- 分子成像
- 生物化学
背景情况:
- 现有的分子成像技术缺乏直接可视化活细胞膜动态的探测器.
- 细胞膜表现出复杂的动态和纳米级异质性,这对细胞功能至关重要.
研究的目的:
- 开发高分辨率,实时成像活细胞膜动态的新型活动探测器.
- 使用新探针研究膜异质性,外体释放和膜蛋白相互作用.
主要方法:
- 采用酶触发器,光体和胆固醇用于细胞膜亲和力的酶响应探针的设计.
- 使用ectophosphatase活动触发探针组合和光在等离子体膜.
- 使用高分辨率显微镜监测膜动态和细胞过程.
主要成果:
- 这些新型探针具有水溶性,与细胞相容,并且在等离子膜中快速组装.
- 探测器在微分子度下表现出强烈的光,使其能够进行高空间和时间分辨率的成像.
- 成功监测了纳米级膜异质性,外体释放和活细胞膜动态.
结论:
- 开发的探针提供了直接成像活细胞膜动态和异质性的方便方法.
- 这种方法有助于理解膜动力学,细胞过程和蛋白质相互作用之间的联系.
- 提供一个强大的工具来推进活细胞成像和细胞生物学研究.
相关概念视频
Protein Dynamics in Living Cells
2.7K
Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
2.7K
¹H NMR of Labile Protons: Temporal Resolution
1.7K
Protons bonded to heteroatoms such as nitrogen and oxygen exhibit a range of chemical shift values. This is due to the varying degree of hydrogen bonding between the proton and the heteroatom in other molecules. The extent of hydrogen bonding affects the electron density around the proton, thereby giving different chemical shift values for the protons in the proton NMR spectrum.
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
1.7K
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
1.3K
At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
1.3K
pH Scale
80.4K
Hydronium and hydroxide ions are present both in pure water and in all aqueous solutions, and their concentrations are inversely proportional as determined by the ion product of water (Kw). The concentrations of these ions in a solution are often critical determinants of the solution’s properties and the chemical behaviors of its other solutes. Two different solutions can differ in their hydronium or hydroxide ion concentrations by a million, billion, or even trillion times. A common means of...
80.4K
Dynamic Equilibrium
63.5K
A reversible chemical reaction represents a chemical process that proceeds in both forward (left to right) and reverse (right to left) directions. When the rates of the forward and reverse reactions are equal, the concentrations of the reactant and product species remain constant over time and the system is at equilibrium. A special double arrow is used to emphasize the reversible nature of the reaction. The relative concentrations of reactants and products in equilibrium systems vary greatly;...
63.5K
Scaling
599
In designing and analyzing filters, resonant circuits, or circuit analysis at large, working with standard element values like 1 ohm, 1 henry, or 1 farad can be convenient before scaling these values to more realistic figures. This approach is widely utilized by not employing realistic element values in numerous examples and problems; it simplifies mastering circuit analysis through convenient component values. The complexity of calculations is thereby reduced, with the understanding that...
599


