相关实验视频
Updated: Feb 13, 2026

05:17
Preparation of High-Quality Fermented Fish Product
Published on: August 23, 2019
11.0K
静脉血栓栓塞质量测量不能准确地测量质量
Brandyn D Lau1,2,3,4, Michael B Streiff3,5,6, Peter J Pronovost3,7,4
1Russell H. Morgan Department of Radiology and Radiological Science (B.D.L.) blau2@jhmi.edu.
Circulation
|March 21, 2018
概括
目前的医院质量测量无法充分评估静脉血栓塞栓症 (VTE) 的预防. 提出一个新的标题来评估无缺陷的静脉瘤预防,包括风险评估,预防处方和更好的患者安全.
科学领域:
- 改善医疗保健的质量
- 患者安全
- 血栓形成研究
背景情况:
- 静脉血栓塞栓症 (VTE) 是可预防的医院伤害的主要原因.
- 多个医疗机构优先测量VTE的结果,以减少发病率和伤害.
- 目前的质量措施还不能充分体现VTE预防的复杂性.
研究的目的:
- 为评估无缺陷静脉血栓塞栓症 (VTE) 的预防制定一个标题.
- 评估现有的VTE质量措施的充分性.
- 确定VTE预防的理想过程和结果措施.
主要方法:
- 开发一个无缺陷的静脉瘤预防的标题.
- 组织的VTE质量指标与标题的分级.
- 对有效的静脉突发症预防的多因素组件的分析.
主要成果:
- 现有的VTE质量措施不充分描述了预防工作和结果.
- 有效的静脉瘤预防需要综合风险评估,处方和管理.
- 一个理想的过程措施包括记录的风险评估,适当的预防处方和处方的预防.
结论:
- 目前的VTE质量措施不足以进行全面评估.
- 需要一个无缺陷的静脉瘤预防标签来提高患者的安全性.
- 根据工艺故障定义可能可预防的VTE对于结果测量至关重要.
相关概念视频
Quality Control
2.9K
Quality control is one of the three cyclical quality assurance activities that help keep a system under statistical control. Typical quality control activities include creating quality control charts, conducting proficiency testing, and documenting and archiving results.
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
2.9K
Quality Assurance
2.5K
Quality assurance is the overarching term used to describe the activities employed to ensure the proper performance of a system. These activities can be classified into three categories: quality control, quality assessment, and internal corrective measures. Typically, these activities work cyclically: quality control is performed before and during the analysis, while quality assessment occurs during and after the investigation. Internal corrective measures are implemented based on the findings...
2.5K
Quality of Water
576
In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
576
Pulse amplitude and quality
3.2K
Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
3.2K
Testing Water Quality
395
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
395
Protein Folding Quality Check in the RER
5.3K
ER is the primary site for the maturation and folding of soluble and transmembrane secretory proteins. The calnexin cycle is a specific chaperone system that folds and assesses the confirmation of N-glycosylated proteins before they can exit the ER lumen. The primary players of this quality check pipeline are the lectins, ER-resident chaperones, and a glucosyl transferase enzyme. In case the calnexin system in the lumen fails to salvage a misfolded protein, it is transported to the cytoplasm...
5.3K