通过阻断非生产性的形交叉点,有效吸收远红/近红外光的BODIPY光
Pradeep Shrestha1, Komadhie C Dissanayake1, Elizabeth J Gehrmann1
1Department of Chemistry, Iowa State University, 1608 Gilman Hall, Ames, Iowa 50010, United States.
Journal of the American Chemical Society
|August 14, 2020
概括
研究人员开发了新的BODIPY光,可以吸收近红外光,用于深层组织. 这些改进的光具有显著更高的光释放效率,克服了生物分子激活和光疗法的先前限制.
科学领域:
- 摄影化学
- 有机化学
- 生物分子工程
背景情况:
- 光可以通过光控制生物分子的激活.
- 远红/近红外吸收光对于深层组织应用至关重要.
- 现有的近IR BODIPY光具有较低的光释放效率.
研究的目的:
- 为了提高近IR吸收BODIPY光的光释放效率.
- 开发适合深层组织生物分子激活和光疗的光.
- 研究改善光量子产量的策略.
主要方法:
- 合成的甲基化BODIPY光.
- 使用激发状态的动态模拟来识别衰变通道.
- 研究了1,7-二替代物对光释放的作用.
- 使用试剂蓝色排除评估细胞毒性.
- 在HeLa细胞中显示光激活.
主要成果:
- 在700 nm左右强烈吸收的BODIPY光.
- 在 680 nm 获得 4650 M-1 cm-1 的量子效率.
- 与以前的长波Bodipy相比,新型光的量子效率提高了50倍.
- 1,7-diaryl替代改善了量子产量和减少了离子对重组.
- 在20μM度下没有观察到细胞毒性.
结论:
- 抑制非生产性的激发状态衰变通道有效提高光效率.
- 符合限制的甲基化BODIPY结构对近IR光具有前景.
- 开发的光为深层组织应用提供了更高的性能.
- 这种策略为设计更高效的光反应提供了途径.
相关概念视频
Infrared (IR) Spectroscopy: Overview
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
Imaging Biological Samples with Optical Microscopy
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Super-resolution Fluorescence Microscopy
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Focusing of Light in the Eye
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
Photoreceptors and Visual Pathways
At the molecular level, visual signals trigger transformations in photopigment molecules, resulting in changes in the photoreceptor cell's membrane potential. The photon's energy level is denoted by its wavelength, with each specific wavelength of visible light associated with a distinct color. The spectral range of visible light, classified as electromagnetic radiation, spans from 380 to 720 nm. Electromagnetic radiation wavelengths exceeding 720 nm fall under the infrared category, whereas...