具有单分子灵敏度的光编码红外振动光谱
Lukas Whaley-Mayda1, Abhirup Guha1, Samuel B Penwell1
1Department of Chemistry, James Franck Institute, and Institute for Biophysical Dynamics, The University of Chicago, Chicago, Illinois 60637, United States.
Journal of the American Chemical Society
|February 17, 2021
概括
我们开发了光编码红外光谱法 (FEIR), 这种技术为缩阶段的化学分析提供了前所未有的结构灵敏度.
科学领域:
- 分子光谱学
- 化学物理
- 单分子生物物理学
背景情况:
- 单分子技术提供高灵敏度,但缺乏溶液中的结构细节.
- 振动光谱提供了关键的化学信息,但在溶液中的单分子水平上具有挑战性.
研究的目的:
- 开发一种可用于溶液中的单分子振动光谱技术.
- 为了实现单个分子化学分析的高结构灵敏度.
主要方法:
- 连接红外振动吸收到光电子过渡.
- 使用常规远场光学进行光编码红外光谱 (FEIR).
- 使用库马林6作为模型光剂来展示原理.
主要成果:
- 在溶液中使用FEIR光谱学证明单分子灵敏度.
- 振动光谱和放松动态的插图测量
- 引入了FEIR相关谱,这是光相关谱的振动模拟.
结论:
- FEIR光谱能够在溶液中进行单分子振动分析.
- 这项技术对凝聚相化学研究具有前景.
- 进一步的进步可以使FEIR成为分子科学的强大工具.
相关概念视频
Infrared (IR) Spectroscopy: Overview
4.0K
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
4.0K
Total Internal Reflection Fluorescence Microscopy
10.8K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
10.8K
Fluorescence and Phosphorescence: Instrumentation
1.1K
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
1.1K
IR Spectroscopy: Molecular Vibration Overview
3.7K
When Infrared (IR) radiation passes through a covalently bonded molecule, the bonds transition from lower to higher vibrational levels. The fundamental vibrational motions that result in infrared absorption can be classified as stretching or bending vibrations.
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
3.7K
Super-resolution Fluorescence Microscopy
11.9K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
11.9K
Atomic Fluorescence Spectroscopy
670
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which...
670