通过共振红外场放大形交叉点的衍射成像
Daniel Keefer1, Jérémy R Rouxel2, Flavia Aleotti3
1Departments of Chemistry and Physics & Astronomy, University of California, Irvine, California 92697-2025, United States.
Journal of the American Chemical Society
|August 17, 2021
概括
研究人员使用红外线在光化学反应中放大状交叉点的弱信号. 这种技术增强了对这些关键的过渡状态的检测,如阿佐光异构化.
科学领域:
- 摄影化学
- 化学物理
- 光谱学
背景情况:
- 圆交点在光化学反应中至关重要,它们调解了快速的电子状态变化.
- 由于弱信号往往被其他贡献所掩盖,用光谱直接观察形交叉点是具有挑战性的.
研究的目的:
- 开发一种提高形交叉点光谱检测的方法.
- 研究共振红外场对圆交叉动态的影响.
主要方法:
- 使用时间解析的X射线衍射探测分子动力学.
- 在亚烯光异构化中的圆交叉通道中应用共振红外场.
主要成果:
- 这种共振红外场显著增强了与形交叉通道相关的连贯性特征.
- 应用领域没有改变光异构反应的总产品产量.
结论:
- 可以使用共振红外场来放大来自形交叉点的过渡状态信号.
- 这种方法为克服光化学过程中形交叉点的检测极限提供了有希望的途径.
相关概念视频
Phase Contrast and Differential Interference Contrast Microscopy
11.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
11.2K
Confocal Fluorescence Microscopy
18.0K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
18.0K
Interference and Diffraction
49.5K
Interference is a characteristic phenomenon exhibited by waves. When two electromagnetic waves interact with their peaks and troughs coinciding, a resulting wave with enhanced amplitude is produced. This is known as constructive interference. In this case, the two waves interacting are in phase with each other.
49.5K
Total Internal Reflection Fluorescence Microscopy
9.6K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
9.6K
IR Spectrometers
1.6K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.6K
Super-resolution Fluorescence Microscopy
10.7K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
10.7K