连续和极化调节的电解电容离子传感器在电活性接口
Sophie C Patrick1, Robert Hein1, Paul D Beer1
1Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, U.K.
Journal of the American Chemical Society
|November 3, 2021
概括
氧电容光谱为实时离子检测提供了一种新方法. 这种可适应的技术为环境和医疗应用提供了灵敏和可调的检测.
科学领域:
- 电化学
- 材料科学
- 分析化学
背景情况:
- 连续的实时离子传感对于环境和医疗应用至关重要,但目前尚未得到充分发展.
- 现有的传感方法往往缺乏灵敏度,适应性或实时监控能力.
研究的目的:
- 证明氧化还原电容光谱是一种敏感且可适应的离子传感方法.
- 展示使用自组装单层的离子连续流传感.
主要方法:
- 使用氧化还原电容光谱检测离子.
- 采用氧化还原活性聚胺自组合单层用于离子检测.
- 在恒定的电极极化下监控氧化还原电容.
主要成果:
- 在离子结合时证明了氧化还原分布和电容的可逆调制.
- 取得了简单而直接的感官读数.
- 调整了传感器性能和离子结合亲和力,
- 在分析性能和适应性方面表现优于标准的电压测量方法.
结论:
- 反氧电容光谱是开发高度敏感和可调节的离子传感器的一个有前途的技术.
- 这种方法提供了一种新的方法,用于同时调节和监测 redox-active 接口上的宿主-客户互动.
相关概念视频
Interfacial Electrochemical Methods: Overview
512
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
512
Dielectric Polarization in a Capacitor
5.2K
The presence of a dielectric medium in a capacitor not only changes the voltage and capacitance but also affects the electric field. In general, dielectrics can be of two types: polar and nonpolar. In a polar dielectric, the positive and negative charges in the molecules are separated by a distance and hence have a permanent dipole moment. In contrast, no such charge separation exists in a nonpolar dielectric, however the nonpolar molecules get polarized in the presence of an external electric...
5.2K
Potentiometry: Membrane Electrodes
878
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
878
Controlled-Potential Coulometry: Electrolytic Methods
337
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
The chosen potential...
337
Potentiometry: Types of Electrodes
1.0K
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
1.0K
Controlled-Current Coulometry: Overview
375
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
375