印度电力部门的气候和空气污染政策对地方的影响
Shayak Sengupta1, Peter J Adams1, Thomas A Deetjen2
1Department of Engineering and Public Policy, Carnegie Mellon University, Pittsburgh, PA, USA.
概括
印度的电力部门面临着减少排放的挑战, 气候和空气污染政策显示各州的影响和成本不同.
科学领域:
- 环境科学
- 能源政策
- 减缓气候变化
背景情况:
- 印度电力部门的温室气体和空气污染物排放对全球气候变化和公共卫生问题有重大影响.
- 了解该行业的排放对于制定有效的减排战略至关重要.
研究的目的:
- 估计印度电力部门的当前排放量.
- 模拟国家气候变化和空气污染政策的后果.
主要方法:
- 分析印度电力部门目前的排放数据.
- 模拟建模以评估国家层面的政策影响.
主要成果:
- 碳税显示短期的排放减少是由于可发送的低排放能力不足以取代煤炭.
- 从国家层面的决定转向区域运输市场并没有减少排放.
- 尽管国家政策的整体效果不大,但各州的影响各不相同.
- 基于生产或消费的定价机制导致各州的成本显著不同.
结论:
- 印度的电力部门需要在低排放能力上进行大量投资以有效减少排放.
- 政策设计必须考虑国家层面的差异,以确保公平的结果和有效的缓解.
- 未来的政策干预应集中在增强可发送的清洁能源和解决国家特定的经济影响上.
相关概念视频
What is Climate?
18.8K
Climate refers to the prevailing weather conditions in a specific area over an extended period. As the saying goes, “Climate is what you expect. Weather is what you get.” Climate is influenced by geographic factors, such as latitude, terrain, and proximity to bodies of water.
18.8K
Secondary Distribution
123
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
123
Power System Distribution
297
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
297
Conservation of AC Power
376
The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
376
Distribution Reliability and Automation
145
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
145
Primary Distribution
141
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
141


