通过珠子喷射机制对多域蛋白进行原生电喷离
Nina Khristenko1, Frédéric Rosu2, Eric Largy1
1Université de Bordeaux, CNRS, INSERM, ARNA, UMR5320, U1212, IECB, PessacF-33600, France.
Journal of the American Chemical Society
|December 27, 2022
概括
原生离子流动性质谱显示了溶液中的多种治疗蛋白质. 一个新的"珠子弹射机制"解释了这些复杂的结构如何在电喷射过程中离子化,进步生物分子分析.
科学领域:
- 生物物理特征
- 质谱学
- 蛋白质科学
背景情况:
- 原生离子移动性质谱法 (IM-MS) 通过电荷和碰撞横截面分布来分析蛋白质溶液构造.
- 治疗性蛋白质通常具有多域结构与无序的链接器,呈现复杂的分析挑战.
研究的目的:
- 使用IM-MS研究多域治疗蛋白质的充电和气相构造.
- 阐明这些复杂的蛋白质结构在电喷射电离过程中的电离机制.
主要方法:
- 原生离子移动性质谱 (IM-MS).
- 溶液中的与交换 (HDX).
- 电荷和碰撞截面分布的分析.
主要成果:
- 多模电荷和碰撞截面分布表明多个溶液构造.
- 溶液中的与交换证实了多种形状的存在.
- 一种称为"珠子弹射"的混合电离机制被提出,以解释不遵循标准模型的结构的电离.
结论:
- 多域蛋白具有复杂的溶液构造,可以通过IM-MS检测.
- 这种"珠子喷射机制"为生物分子在电子喷射中的离子化提供了新的解释.
- 这种机制可能是各种生物分子的电子喷射电离的一般原理.
相关概念视频
Electrospray Ionization (ESI) Mass Spectrometry
1.0K
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
1.0K
Peptide Identification Using Tandem Mass Spectrometry
6.7K
Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
6.7K
Chemical Ionization (CI) Mass Spectrometry
824
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
824
Capillary Electrophoresis: Instrumentation
304
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
304
Capillary Electrophoresis: Applications
488
Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
488