暂时刺激拉曼刺激光谱
Qiaozhi Yu1, Zhengjian Yao1, Haolin Zhang2,3
1National Biomedical Imaging Center, College of Future Technology, Peking University, Beijing 100871, China.
Journal of the American Chemical Society
|March 30, 2023
概括
暂时刺激的拉曼激发光 (T-SREF) 实现无背景的单分子拉曼光谱. 这种超快的时域光谱法提高了高级分子分析的灵敏度.
科学领域:
- 光学和光谱学
- 化学物理
- 分子光谱学
背景情况:
- 拉曼光谱的目的是提高灵敏度,这对于分子分析至关重要.
- 目前的单分子拉曼光谱法面临着光背景和激发的挑战.
- 现有的频域技术缺乏高效的高光谱激发.
研究的目的:
- 为无背景拉曼光谱开发超快的时间域光谱法.
- 克服现有的频域拉曼光谱的局限性.
- 为了实现分子检测和动态传感的高灵敏度.
主要方法:
- 引入过渡激发拉曼光 (T-SREF),是一种超快的时间域技术.
- 使用两个连续的宽带五秒脉冲对 (和斯托克斯脉冲) 与时间延迟扫描.
- 应用里埃转换到时间域光痕迹显示振动波包干扰.
主要成果:
- T-SREF成功生成了电子合振动模式的无背景拉曼光谱.
- 在几个分子的水平上达到灵敏度.
- 在时间域光中证明了振动波束干扰.
结论:
- T-SREF为频域拉曼光谱提供了一个强大的替代方案.
- 该方法可实现超多重光检测和分子动态传感.
- T-SREF显著提高了拉曼光谱的灵敏度和适用性.
相关概念视频
Raman Spectroscopy: Overview
490
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
490
Total Internal Reflection Fluorescence Microscopy
5.9K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
5.9K
Raman Spectroscopy Instrumentation: Overview
479
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
479
Protein Dynamics in Living Cells
2.2K
Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
2.2K