使用快速S转换和随机森林的T型电网连接逆变器的开放电路故障检测
Li You1, Zaixun Ling1, Yibo Cui1
1State Grid Hubei Electric Power Research Institute, Wuhan 430077, China.
Entropy (Basel, Switzerland)
|May 27, 2023
概括
本研究引入了一种使用快速S转换和随机森林的新实时方法,用于检测连接到电网的T型逆变器中的开放电路故障. 该技术在没有额外传感器的情况下达到100%的准确性,确保可靠的逆变器监控.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
- 错误诊断 错误诊断 错误诊断 是一个
背景情况:
- 连接到电网的T型逆变器对于可再生能源的整合至关重要.
- 开放电路故障会降低性能,并构成安全风险.
- 有效的故障检测对于可靠的逆变器运行至关重要.
研究的目的:
- 提出一种新的实时方法,用于检测连接到电网的T型逆变器中的开放电路故障.
- 为了在没有额外的传感器的情况下实现高精度和高效的故障检测.
主要方法:
- 使用三相断电流作为输入数据.
- 使用快速S转换来从断裂电流中提取特征.
- 应用随机森林算法用于故障识别,分类和开关定位.
主要成果:
- 实现了对开放电路故障的100%检测准确度.
- 证明了实时应用的低计算复杂性.
- 通过模拟和实验测试验证了该方法.
结论:
- 提出的方法是有效的实时,准确的开放电路故障检测在连接到电网的T型逆变器.
- 这种方法消除了对额外传感器的需求,简化了实施.
- 这种技术提高了逆变器监控系统的可靠性和安全性.
相关概念视频
Power System Three-Phase Short Circuits
115
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
115
Fast Decoupled and DC Powerflow
245
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
245
Three-Phase Short Circuit—Unloaded Synchronous Machine
172
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
172
Bus Impedance Matrix
152
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
152
Fault Types
110
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
110
Reclosers and Fuses
142
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
142