在处理具有多变量曲线分辨率的染色谱二阶数据时,模拟背景信号的新约束
Maira D Carabajal1, Rocío Pellegrino Vidal2, Juan A Arancibia1
1Departamento de Química Analítica, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Instituto de Química Rosario (CONICET-UNR), Suipacha 531, 2000, Rosario, Argentina.
Analytica chimica acta
|May 27, 2023
概括
使用多变量曲线分辨率交替最小平方 (MCR-ALS) 的化学测量分析可以得到改进. 一个新的背景插值约束减少了染色谱数据处理中的模两可.
科学领域:
- 化学测量 化学测量 化学测量
- 分析化学 分析化学
- 频谱学是一种光谱学.
背景情况:
- 多变量曲线分辨率交替最小方形 (MCR-ALS) 是处理二次色谱数据的标准.
- 数据的基线贡献可能会导致MCR-ALS检索的背景配置文件中的异常块或负下降.
研究的目的:
- 为了解决MCR-ALS中异常特征,检索了由基线贡献引起的背景资料.
- 为改进染色谱数据的MCR-ALS分析引入一个新的约束.
主要方法:
- 开发并描述了MCR-ALS.的新背景插值约束.
- 利用模拟和实验色谱谱数据进行验证.
- 评估了约束对旋转模糊性的影响.
主要成果:
- 新的约束有效地减轻了可检索的背景配置文件中的异常块和负下降.
- 减少了MCR-ALS解决方案中的旋转模糊性.
- 来自实验数据的分析剂度与之前报告的值保持一致.
结论:
- 拟议的背景插值约束提高了MCR-ALS.的可靠性.
- 从处理的数据中改进了物理化学性质的解释.
- 减少了用于染色谱数据分析的MCR-ALS解决方案中的模两可.
相关概念视频
Chromatographic Resolution
549
In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
549
Chromatographic Methods: Terminology
2.3K
Chromatography is an analytical technique widely used in fields such as chemistry, biology, environmental science, and pharmaceuticals to separate the components of a mixture and identify substances between them. The process of chromatography is based on the interactions between two distinct phases: the stationary phase and the mobile phase. The stationary phase is fixed in place by a supporting material, while the mobile phase moves over it, carrying the solutes. As the mobile phase travels,...
2.3K
Chromatographic Methods: Classification
2.4K
Chromatographic techniques are classified in three ways: the classification is based on the physical state of the stationary and mobile phases, how the mobile phase and the stationary phase contact each other, or through the chemical or physical processes that isolate the components of the sample. Typically, the mobile phase is either a liquid or gas, while the stationary phase is either a solid or a liquid layer applied to a solid surface.
Chromatographic techniques are typically named by...
Chromatographic techniques are typically named by...
2.4K
NMR Spectrometers: Resolution and Error Correction
740
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
740
¹H NMR: Interpreting Distorted and Overlapping Signals
1.1K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.1K
Optimizing Chromatographic Separations
442
Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
442