导电性MXene超膜,以改善电化学辅助下的防能力和水质
Lulu Qian1, Chengyu Yuan1, Xu Wang1
1Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education, China), School of Environmental Science and Technology, Dalian University of Technology Dalian 116024 China shuochen@dlut.edu.cn +86-411-84706263.
RSC advances
|May 30, 2023
概括
这项研究引入了一种导电的MXene超膜,可以显著减少水处理中的膜污染. 电化学辅助增强了膜流和污染物去除,显示了先进净化水的巨大潜力.
科学领域:
- 材料科学 材料科学 材料科学
- 环境工程 环境工程
- 电化学 电化学 电化学
背景情况:
- 膜污染严重限制了超过在水处理中的效率.
- 开发具有增强防性质的膜对于可持续的水净化至关重要.
研究的目的:
- 准备和评估MXene超膜,以提高防腐蚀性.
- 为了研究电化学辅助对膜性能的影响.
主要方法:
- 制造一种电导和水的MXene超膜.
- 在水处理过程中应用电化学辅助 (负电位和2.0V外部电压).
- 评估膜流量,总有机碳 (TOC) 去除和再生能力.
主要成果:
- 与没有外部电压相比,MXene膜在电化学辅助下表现出明显更高的流量 (2.4-3.4倍).
- 对实际地表水的处理显示,流量增加了1.6倍,TOC去除率从60.7%提高到71.2%.
- 强化静电排斥被确定为减少污染的主要机制.
- 膜表现出良好的再生能力,在反冲洗后保持稳定的TOC去除率约为70.7%.
结论:
- 在电化学辅助下,MXene超膜表现出卓越的防性能.
- 这项技术在先进的水处理应用中具有重大潜力.
- 电化学辅助有效地提高了膜流和污染物去除效率.
相关概念视频
Dialysis
739
Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
739
Ion Exchange
627
Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
627
Potentiometry: Membrane Electrodes
643
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
643