相关实验视频
Updated: Jul 28, 2025

08:51
Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
9.1K
一个模块化系统的灵活的只接收线圈阵列为3T磁共振成像
Lena Nohava1, Michael Obermann1, Roberta Frass-Kriegl1
1High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Zeitschrift fur medizinische Physik
|May 31, 2023
概括
新型ModFlex线圈系统为磁共振成像 (MRI) 提供高信号噪声比 (SNR),提高成像速度和分辨率. 这种灵活的模块化线圈阵列在各种解剖区域和患者大小中展示了多功能性.
科学领域:
- 医疗成像医学成像
- 生物物理学的生物物理.
- 工程 工程师 工程师 工程师
背景情况:
- 灵活的射频线圈提高了磁共振成像 (MRI) 中的信号噪声比 (SNR).
- 这些线圈的阵列配置可以覆盖很大的解剖区域.
- 模块化线圈系统为各种成像需求提供适应性.
研究的目的:
- 介绍和评估一个模块化,灵活,轻量级的4通道同轴线圈阵列系统ModFlex为3特斯拉 (3T) MRI的性能.
- 为了比较8和16通道ModFlex系统与商业参考线圈的性能,在体内.
- 评估ModFlex系统在不同解剖区域和用例中的多功能性和稳定性.
主要方法:
- 开发一个模块化,灵活,轻量级的4通道同轴线圈阵列系统 (ModFlex) 用于3TMRI.
- 在使用ModFlex系统的部,脚,脊柱和部的六个解剖目标的体内成像.
- 与商业参考线圈的ModFlex阵列 (8频道和16频道) 的性能比较,重点是SNR和并行成像功能.
主要成果:
- 与商业卷轴相比,ModFlex系统在6个解剖目标区域中的4个实现了更高的SNR;在剩余的2个区域中,SNR类似.
- ModFlex 的并行成像性能与用于部和部成像的标准线圈相当.
- 与标准卷轴相比,ModFlex在脚和脊柱成像中表现出优异的并行成像性能.
结论:
- ModFlex系统提供高SNR和强大的并行成像功能,使得更快,更高分辨率的MRI采集成为可能.
- 线圈的灵活性,轻量化设计和模块化性增强了各种患者大小的多功能性,并提高了舒适性.
- 在临床环境中,ModFlex显示出优化MRI工作流程和患者体验的巨大潜力.
相关概念视频
Magnetic Resonance Imaging
5.3K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.3K
Imaging Studies IV: Magnetic Resonance Imaging
37
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
37
Magnetic Field Due to Two Straight Wires
2.7K
Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
2.7K
Magnetic Field Of A Current Loop
4.7K
Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
4.7K
Magnetic Field Due To A Thin Straight Wire
4.9K
Consider an infinitely long straight wire carrying a current I. The magnetic field at point P at a distance a from the origin can be calculated using the Biot-Savart law.
4.9K
Imaging Studies for Cardiovascular System IV: CMRI
65
Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
65

