将PM与PM进行比较
Therese Nitter Moazami1, Kristin V Hirsch Svendsen1, Morten Buhagen2
1Department of Industrial Economics and Technology Management (IØT), Norwegian University of Science and Technology (NTNU), 7491, Trondheim, Norway.
Heliyon
|June 5, 2023
概括
与重力测量样本相比,DustTrak DRX监视器在测量尘埃度时显示了不准确的情况. 总尘埃读数需要一个校正系数,以准确评估职业暴露限值.
科学领域:
- 职业健康和安全问题 职业健康和安全问题
- 环境监测 环境监测
- 工业卫生 工业卫生
背景情况:
- 实时尘埃监测器为职业暴露评估提供了潜在的优势.
- 传统的重力测量采样是测量尘埃度的标准.
- 评估实时监控器的准确性对于可靠的暴露评估至关重要.
研究的目的:
- 为了评估DustTrak DRX监控器与重力测量样本的精度.
- 确定实时监控器对于职业粉尘暴露监测的适用性.
- 为了研究DustTrak DRX与不同灰尘材料的性能.
主要方法:
- 暴露室实验进行了19天,每天进行4小时的测量.
- 将DustTrak DRX实时监控数据与传统的重力测量样本进行了比较.
- 用于青和乳糖粉中的两种石矿物质被用作暴露材料.
主要成果:
- 在DustTrak DRX中,高估了PM2.5和可呼吸尘埃的度.
- 总尘埃度被DustTrak DRX低估了近两倍的因素.
- DustTrak DRX和重力测量样本之间的差异每天和根据材料而异.
结论:
- 对于DustTrak DRX的总尘埃读数,建议使用至少2的校正系数.
- 实时监控器可以识别暴露源,并有助于控制策略的评估.
- 当使用DustTrak DRX进行职业暴露分析时,需要仔细解释和潜在验证.
相关概念视频
Multiple Comparison Tests
3.9K
Multiple comparison test, abbreviated as MCT, is a post hoc analysis generally performed after comparing multiple samples with one or more tests. An MCT will help identify a significantly different sample among multiple samples or a factor among multiple factors.
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
3.9K
Methods of Documentation II: POMR
1.0K
The Problem-Oriented Medical Record (POMR) revolutionized medical record-keeping by introducing a systematic approach focusing on the patient's problems rather than merely listing symptoms. Dr. Lawrence Weed's introduction of this method in the 1960s marked a significant advancement in medical documentation. The POMR framework consists of four key components: the database, problem list, plan of care, and progress notes.
1.0K
¹H NMR: Pople Notation
1.8K
The Pople nomenclature system classifies spin systems based on the difference between their chemical shifts. Coupled spins are denoted by capital letters with subscripts indicating the number of equivalent nuclei. When the coupled nuclei have well-separated chemical shifts, they are assigned letters that are far apart in the alphabet, such as A and X. When the difference in chemical shifts is small, coupled nuclei are named using adjacent letters of the alphabet (AB, MN, or XY).
A proton...
A proton...
1.8K