一起或分开:在为类风湿性关节炎检查进行双边手部成像时,什么是最佳实践?
Annabel Keir1, Vicki Braithwaite2
1Department of Medical Imaging, The Prince Charles Hospital, Chermside, Queensland, Australia.
Journal of medical radiation sciences
|June 7, 2023
概括
对于类风湿性关节炎 (RA) 的成像,双边手部检查的单边技术提供了卓越的图像质量,辐射剂量增加最小. 由于扭曲率降低,建议采用这种方法,而不是同步成像.
科学领域:
- 医疗成像医学成像
- 放射学 放射学 放射学 放射学
- 类风湿性关节炎 诊断 诊断
背景情况:
- 医疗成像中双边手部检查的标准化协议缺乏.
- 同时与单边手部成像影响辐射剂量和图像质量,这对于类风湿性关节炎 (RA) 患者的护理至关重要.
研究的目的:
- 为了比较单边和并发双边手部放射技术之间的辐射剂量和图像质量.
- 为了确定类风湿性关节炎评估的最佳成像方法.
主要方法:
- 使用人类形手幻象进行实验研究.
- 辐射剂量通过剂量面积产物 (DAP) 和曝光仪测量.
- 通过测量光束分歧扭曲来评估图像质量.
主要成果:
- 单边技术导致辐射剂量增加10.15-11.96%.
- 单边技术产生了0毫米的扭曲,而并发技术显示了3.65毫米的平均扭曲.
- 同时成像中的扭曲增加对RA分级具有临床意义.
结论:
- 在RA成像中,建议单边技术用于双边手部检查.
- 由单边技术改善的图像质量超过了最小的辐射剂量增加.
- 需要标准化的协议来优化诊断准确性和患者安全.
更多相关视频
05:18Author Spotlight: Ultrasound-Guided Needle Release Combined with Corticosteroid Injection for the Treatment of Supinator Syndrome
Published on: May 26, 2023
1.5K
04:50Preliminary Study on Acupuncture Combined with Grain-sized Moxibustion for Treating Rheumatoid Arthritis with Finger Joint Pain
Published on: May 16, 2025
271
相关概念视频
Assessment of radial pulse
889
Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
889
Pre-Procedural Guidelines for Assessing Blood Pressure
601
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
601
Assessment of apical radial pulse
803
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
803
