圆束CT采样不完整性:对新兴系统和源探测器轨道的分析和实证研究
Pengwei Wu1, Aina Tersol1, Rolf Clackdoyle2
1Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.
Journal of medical imaging (Bellingham, Wash.)
|June 9, 2023
概括
先进的圆束计算机断层扫描 (CBCT) 轨道提高了3D图像重建的数据完整性. 新的方法量化评估形光束工件,有助于开发更好的CBCT系统.
科学领域:
- 医疗成像医学成像
- 辐射物理学 辐射物理学
背景情况:
- 圆束计算断层扫描 (CBCT) 系统正在发展,具有新的扫描轨道.
- 评估数据完整性对于准确的3D图像重建和最大限度地减少形光束文物至关重要.
研究的目的:
- 在新兴的CBCT系统中对3D图像重建的数据完整性进行定量评估.
- 分析束采样不完整性和文物分析和实证测量之间的关系.
主要方法:
- 分析了一种分析价值 (FOM),tan(ψmin),表示采样不完整.
- 使用一个带有盘对的物理测试幻影来测量形光束文物大小 (zmod).
- 评估了两个CBCT系统 (C臂和四肢) 使用各种轨道,包括圆形,半圆形,多源和正弦球 (SoS).
主要成果:
- 在分析FOM (tan(ψmin)) 和经验FOM (zmod) 之间表明了明确的关系.
- 像三源和SoS轨道这样的先进轨道显示出卓越的采样完整性.
- 测试幻象和zmod指标有效量化了CBCT几何和轨道的变化,作为取样完整性的替代品.
结论:
- 对于CBCT系统,形束采样的完整性可以通过分析和实证量化.
- 这一分析为新CBCT技术和轨迹的采样效应提供了理论和实践的见解.
更多相关视频
相关概念视频
Computed Tomography
4.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.6K
Imaging Studies III: Computed Tomography
30
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
30
Imaging Studies I: CT and MRI
306
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
306
Electron Microscope Tomography and Single-particle Reconstruction
2.4K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.4K
Scanning Electron Microscopy
4.3K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.3K