通过固体采样,电热蒸发与感应合等离子光学发射光谱学相结合的法医分析
Kate Moghadam1, Diane Beauchemin1
1Department of Chemistry, Queen's University, 90 Bader Lane, Kingston, ON K7L 3N6, Canada. diane.beauchemin@queensu.ca.
概括
固体采样电热蒸发与感应合等离子光学发射光谱学 (ETV-ICPOES) 结合,为法医痕迹证据分析提供了一种敏感的方法. 这种技术允许使用最小的样本数量精确识别和区分证据.
科学领域:
- 法医科学 法医科学 法医科学
- 分析化学 分析化学
- 频谱测量是一种光谱测量.
背景情况:
- 法医痕迹证据分析需要非破坏性或最小样本技术.
- 固体采样电热蒸发与感应合的等离子光学发射光谱学 (ETV-ICPOES) 是一种合适的技术,只需要0.1-5毫克的样品.
研究的目的:
- 讨论ETV-ICPOES在法医证据分析方面的能力.
- 突出其在识别,确定和歧视证据方面的价值.
主要方法:
- 审查ETV-ICPOES用于直接分析实物和痕迹证据的方法.
- 应用矩阵匹配的外部校准和内部标准化.
- 使用多变量分析 (PCA,LDA) 进行定性多元件分析.
主要成果:
- ETV-ICPOES展示了证据识别和歧视的各种机会.
- 方法允许对多个元素进行量化和定性多元元素分析.
- 内部标准化有效地弥补了样本加载效应.
结论:
- ETV-ICPOES是法医追踪证据分析的一个有价值的工具.
- 最新的进展为证据审查提供了多样化的机会.
- 未来的法医设置可以从ETV-ICPOES的利用中受益.
相关概念视频
Atomic Emission Spectroscopy: Lab
211
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
211
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
712
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
712
Atomic Emission Spectroscopy: Instrumentation
545
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
545
Atomic Emission Spectroscopy: Overview
2.4K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
2.4K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
263
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
263
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
823
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
823