保护性混凝土填充钢板复合墙体低速冲击行为的数值分析
Hongmei Xiao1,2, Peng Yu3,4, Limeng Zhu1,2
1School of Civil Engineering, Qingdao University of Technology, Qingdao 266520, China.
Materials (Basel, Switzerland)
|June 10, 2023
概括
一个新型的防护混凝土填充钢板复合墙 (PSC) 提供了出色的抗震和抗冲击性能. 其可更换的吸收能量层有效地减少了位移并吸收了冲击能量,确保了关键应用中的结构安全.
科学领域:
- 结构工程 结构工程
- 材料科学 材料科学 材料科学
- 土木工程 土木工程是指土木工程.
背景情况:
- 开发先进的复合结构以提高安全性至关重要.
- 现有结构往往缺乏足够的性能来承受联合的地震和冲击负荷.
- 防护混凝土填充钢板复合墙 (PSC) 是一个有前途的解决方案.
研究的目的:
- 开发和研究一种新的防护混凝土填充钢板复合墙 (PSC).
- 为了评估PSC墙的低速度撞击行为.
- 分析各种参数对PSC墙壁冲击性能的影响.
主要方法:
- 精细的有限元模型的开发和验证.
- 模拟飞机外低速撞击场景的模拟.
- 对几何和动态负载参数的研究.
- 塑料产量线理论模型的建议和应用.
主要成果:
- 可更换的能量吸收层可以显著减少外平面和塑料位移.
- 该PSC墙显示了相当大的冲击能量吸收能力.
- 该结构在冲击负载下保持高平面内地震性能.
- 提出的理论模型准确地预测了外平面移位.
结论:
- 开发的PSC壁表现出优越的抗冲击性能和能量吸收.
- 可更换的能量吸收层是提高冲击性能的关键.
- PSC墙适用于高层建筑,民防和严格的安全应用.
- 经过验证的有限元模型和理论模型提供了可靠的设计和分析工具.
相关概念视频
Abrasion Resistance of Concrete
168
Abrasion resistance is an essential characteristic of concrete that determines its durability and longevity under various wear conditions. Concrete surfaces are vulnerable to different types of abrasion. For instance, surfaces may wear down due to the constant movement of vehicles or be eroded by solids carried in water, as seen in concrete canal linings. Specific tests are conducted to measure the abrasion resistance of concrete.
One such test is the revolving disc test, where three plates...
One such test is the revolving disc test, where three plates...
168
Impact Strength of Concrete
261
Impact strength in concrete is a critical measure that reflects the material's capability to endure the forces applied during pile driving and when supporting machinery foundations that experience impulsive loads. It is also essential when handling precast concrete components to prevent accidental damage. The impact strength is assessed by observing the concrete's resistance to repeated impacts and energy absorption capacity. A key indicator of significant damage to concrete is when it...
261
Non-destructive Tests for Concrete Strength
151
The rebound hammer test, also known as the Schmidt hammer test, is a non-destructive technique for evaluating the hardness of concrete and, indirectly, the strength of concrete. It operates on the principle that the rebound of a spring-driven mass from a concrete surface correlates to the surface's hardness. The device comprises a mass within a tubular housing, a spring mechanism, and a plunger that strikes the concrete. Upon release, the energy imparted to the mass by the spring causes it...
151
Behavior of Concrete Under Compressive Load
223
Concrete exhibits specific behaviors under different compressive loads. Understanding this is crucial for understanding its structural integrity. When concrete undergoes uniaxial compression, it tends to develop cracks that run parallel to the direction of the force. These parallel cracks stem from localized tensile stresses that occur perpendicular to the compression direction. Additionally, angled cracks may appear due to the formation of shear planes.
As the concrete specimen fractures under...
As the concrete specimen fractures under...
223
Dynamic Modulus of Elasticity of Concrete
427
The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
427
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
159
Assessing safety in wind-exposed installations is crucial to preventing potential failures. This example explores the calculation and design adjustments needed to mount a circular disc on a building facade, where wind forces are a primary concern. A 4-meter diameter disc was initially designed as an aesthetic feature facing winds at a velocity of 25 meters per second, with an air density of 1.25 kilograms per cubic meter. Given these conditions, the drag force on the disc was determined using...
159