作为高性能pH探测器的超分子模量:对刚性船基复合体中化体的光特性进行研究
Jiajun Xu1, Meifen Huang2, Liang Jiao2
1Department of Chemical Science and Technology, Kunming University, Kunming 650214, China.
International journal of molecular sciences
|June 10, 2023
概括
两个新的基于希夫联体的素化pH传感器表现出增强的光和稳定性. 化改进了信号噪声比和响应范围,由理论计算证实.
科学领域:
- 材料科学 材料科学 材料科学
- 分析化学 分析化学
- 化学传感器 化学传感器
背景情况:
- 高性能光探针对于各种应用至关重要.
- 开发灵敏和稳定的pH传感器仍然是一个活跃的研究领域.
研究的目的:
- 开发基于光的新型高性能pH传感器.
- 为了研究化对传感器性能和机制的影响.
主要方法:
- 合成了两种新的化希夫联体及其复合物 (Zn-3,5-Cl-saldmpn和Zn-3,5-Br-saldmpn).
- 光谱学分析传感器对pH值变化 (5.0-7.0) 的反应.
- 在20个运行周期内进行稳定性和可逆性测试.
- 与非基化类似物进行比较.
- 结构和光学特性. 结构和光学特性.
- 理论计算以阐明光机制.
主要成果:
- 开发的传感器显示了光发射的指数级增长和染色变化,pH值从5.0增加到7.0.
- 传感器在20个周期后保持了超过95%的信号幅度,表明了出色的稳定性和可逆性.
- 化增强了信号与噪声的比率,并扩大了响应范围.
- 理论计算支持了涉及素诱导的分子间相互作用的拟议机制.
结论:
- 新的基于希夫联体的复合物作为有效和稳定的pH传感器起作用.
- 原子在通过分子间相互作用和聚合来提高传感器性能方面发挥着至关重要的作用.
- 这些发现为设计先进的光探针提供了洞察力.
相关概念视频
Variables Affecting Phosphorescence and Fluorescence
547
Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
547
Photoluminescence: Applications
440
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
440
Labeling DNA Probes
8.2K
DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
8.2K
Complexometric Titration: Ligands
1.0K
Different monodentate and polydentate ligands are used as complexing agents in complexometric titration reactions. The formation of complexes by mono- and bidentate ligands involves two or more intermediate steps, limiting their use as complexing agents. In comparison, polydentate ligands can form complexes with metal ions in a single-step process, facilitating sharper end points. This means polydentate ligands, such as amino carboxylic acid derivatives, are most commonly employed in...
1.0K
Colors and Magnetism
12.0K
Color in Coordination Complexes
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
12.0K
Fluorescence and Phosphorescence: Instrumentation
664
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
664