在冷压力测试过程中,与指动脉压力参考指纹动脉压力测试过程中,斑点斑膜学和光斑膜学之间的比较
Jorge Herranz Olazabal1,2, Ilde Lorato1, Jesse Kling1
1IMEC NL, 5656 AE Eindhoven, The Netherlands.
Sensors (Basel, Switzerland)
|June 10, 2023
概括
在低 perfusion 条件下,光斑囊镜 (SPG) 提供比光斑囊镜 (PPG) 更强大的脉冲波监测. 在冷压器测试中,SPG在信号与噪声比率 (SNR) 和波比率方面表现出更高,更稳定的信号与噪声比率.
科学领域:
- 生物光子学 生物光子学
- 医疗器械 医疗器械
- 身体生理学 身体生理学
背景情况:
- 斑点光学 (SPG) 和光光学 (PPG) 是用于血液动力学测量的生物光学技术.
- 了解低 perfusion 下的 SPG 和 PPG 之间的差异至关重要.
- 冷压器试验 (CPT) 有效调节周围循环.
研究的目的:
- 为了比较SPG和PPG在诱导低 perfusion 条件下的性能.
- 在CPT期间评估SPG和PPG的信号噪声比 (SNR) 和交替元件 (AC) 幅度.
- 分析波形差异使用SPG,PPG和手指动脉压 (fiAP) 之间的频率波比.
主要方法:
- 在639nm和850nm波长使用自定义设置同时导出SPG和PPG信号.
- 在60秒CPT之前和期间,用食指进行测量.
- 对两种技术的交流振幅和SNR的分析,使用fiAP作为参考.
- 对SPG,PPG和fiAP波形之间的频率波比进行比较.
主要成果:
- 850nm的PPG和SPG在CPT期间显示了AC和SNR的显著减少.
- 与PPG相比,SPG始终表现出更高和更稳定的SNR.
- SPG显示出比PPG更高的和比率.
结论:
- 在低 perfusion 场景中,SPG 提供比 PPG 更强大的脉冲波监测.
- SPG的优越SNR和律比率表明血液动力学评估的可靠性提高了.
- 双波长SPG在外周循环受到损害时显示出准确的生理监测的希望.
相关概念视频
Sites for measruring blood pressure
1.9K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.9K
Assessment of blood pressure in brachial artery(two-step method)
787
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
787
Assessing Blood pressure using a doppler ultrasound
1.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K
Measurement of Blood Pressure
1.0K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.0K
Special considerations while measuring blood pressure
776
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
776
Assessment of blood pressure in brachial artery(one-step method)
649
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
649