对于5G心脏起器的低损耗MIMO天线无线通信系统
Deepti Sharma1, Binod Kumar Kanaujia1,2, Sachin Kumar3
1School of Computational and Integrative Sciences, Jawaharlal Nehru University, New Delhi, India.
Scientific reports
|June 12, 2023
概括
这项研究展示了用于无线心脏起器的新型双频,双端口MIMO天线,通过5G物联网平台实现可靠的远程心脏健康数据传输. 这项创新通过改进的无线通信来增强心血管疾病管理.
科学领域:
- 生物医学工程 生物医学工程
- 无线通信系统无线通信系统
- 医疗器械 医疗器械
背景情况:
- 心血管疾病 (CVD) 是全球主要的死亡原因.
- 远程监测心脏健康数据对于有效的节拍器管理至关重要.
- 目前用于起器的通信系统在数据传输能力方面存在局限性.
研究的目的:
- 为了首次演示,双频,双端口多输入多输出 (MIMO) 天线系统用于无线心脏起器.
- 为了使内部起器天线和外部监控设备之间的可靠,低损失的无线通信.
- 探索与5G物联网平台和现有4G标准的兼容性,以加强心脏护理.
主要方法:
- 在无线心脏起器中开发和集成一个紧的双频段 (2.45和5.8 GHz ISM频段) 双端口MIMO天线.
- 设计相应的外部双带双端口MIMO天线用于数据接收.
- 对拟议的MIMO天线系统的通信能力进行实验验证,并与单输入单输出 (SISO) 系统进行比较.
主要成果:
- 成功证明了内部无线节拍器MIMO天线和外部MIMO天线之间的通信.
- 在2.45和5.8 GHzISM频段中验证低损耗数据传输.
- 实验结果显示,与传统的SISO通信相比,MIMO系统的性能优越.
结论:
- 拟议的双频MIMO天线系统为先进的无线节拍器通信提供了一个有希望的解决方案.
- 这项技术支持与5G物联网平台的集成,为下一代远程心脏监测铺平了道路.
- 该系统提高了向医疗专业人员传输重要心脏健康数据的可靠性和效率.
相关概念视频
Mesh Analysis for AC Circuits
399
In the domain of radio communication, the significance of impedance matching must be considered. It is crucial to ensure the efficient transmission of signals between radio transmitters and receivers. Achieving this balance involves using impedance-matching circuits, with one fundamental configuration comprising a resistor, capacitor, and inductor.
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
399
Transmission Line Design Considerations
177
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
177
Mitral Stenosis III: Medical Management
14
Mitral stenosis, a condition marked by the narrowing of the mitral valve, necessitates an integrated approach for effective management. This approach includes preventative measures, medical therapy, and surgical interventions to reduce symptoms and prevent complications.PreventionPrevention of mitral stenosis primarily focuses on reducing the incidence of bacterial infections, particularly streptococcal infections, which can lead to rheumatic fever and subsequent valvular damage. Timely...
14
Mitral Regurgitation III: Medical Management
20
Mitral regurgitation (MR) is characterized by retrograde blood circulation from the left ventricle into the left atrium due to inadequate mitral valve closure. The severity of the condition, symptoms, and underlying cause determine treatment strategies.Monitoring and Pharmacological TreatmentPatients with mild to moderate MR typically do not need immediate intervention but regular monitoring to assess progression and guide treatment. Patients with mild MR should have an echocardiogram every 3-5...
20
Energy Stored In A Coaxial Cable
1.6K
A coaxial cable consists of a central copper conductor used for transmitting signals, followed by an insulator shield, a metallic braided mesh that prevents signal interference, and a plastic layer that encases the entire assembly.
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic...
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic...
1.6K