预加载的托里克眼内透镜植入眼睛的结果经历了法可化
Ritu Nagpal1, Chetan Shakkarwal1, Saima Ahsan1
1Department of Ophthalmology, Cataract, Cornea and Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Indian journal of ophthalmology
|June 16, 2023
概括
预装的托里克眼内透镜 (IOL) 植入物有效地纠正白内障手术后的. 在SupraPhob toric IOL显示出出色的视觉结果和稳定性,没有任何并发症.
科学领域:
- 眼科医生 眼科 眼科
- 生物医学工程 生物医学工程
- 临床研究 临床研究
背景情况:
- 白内障手术,特别是发光乳化,是恢复视力的常见手术.
- 预先存在的角膜形症可能会在标准眼内透镜 (IOL) 植入后对视觉结果产生负面影响.
- 托里克内膜透镜的设计是为了同时纠正白内障移除的同时纠正.
研究的目的:
- 评估预加载的托里克眼内透镜 (IOL) 植入眼睛中的临床结果.
- 评估SupraPhob toric IOL在白内障手术期间用于纠正的疗效和安全性.
主要方法:
- 这是一项前性研究,涉及51名白内障和角膜形 (0.75-5.50 D) 患者.
- 在局部麻醉下使用预装的SupraPhob托里克IOL植入物进行法化.
- 结果措施包括未经校正的距离视敏度 (UDVA),折射筒,球形等效,以及3个月后的IOL稳定性.
主要成果:
- 在UDVA显著改善,49%的人达到20/25或更好,所有眼睛都比20/40好.
- 平均logMAR UDVA从1.02提高到了0.11 (P < 0.001). 平均logMAR UDVA从1.02提高到了0.11 (P < 0.001). 平均logMAR UDVA从1.02提高到了0.11 (P < 0.001). 平均logMAR UDVA从1.02提高到了0.11 (P < 0.001).
- 平均折射力筒从-1.56 D减少到-0.12 D (P < 0.001),球形等价物显著改善.
- IOL旋转稳定性很好,在3个月 (1.7 ± 1.61度) 观察到最小的旋转.
- 没有报告任何手术内或术后并发症.
结论:
- SupraPhob toric IOL植入是一种有效的方法,可以在发酵过程中纠正先前存在的角膜形.
- 该程序提供了良好的视觉结果和出色的旋转稳定性.
- 这种眼镜为寻求在白内障手术后改善视力的患者提供了安全有效的解决方案.
相关概念视频
Angle Closure Glaucoma: Treatment
578
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
578
Glaucoma: Overview
633
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
633
Open Angle Glaucoma: Treatment
491
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
491


