确定低成本传感器的最佳同位点校准周期
Misti Levy Zamora1,2,3, Colby Buehler3,4, Abhirup Datta5
1University of Connecticut Health Center, Department of Public Health Sciences UConn School of Medicine, 263 Farmington Avenue, Farmington, CT, USA 06032-1941.
概括
优化传感器校准周期对于准确的空气质量监测至关重要. 战略性地选择同位时间,即使只需一周,也可以为测量颗粒物和气体的传感器提供一致的结果.
科学领域:
- 环境科学 环境科学
- 大气化学 大气化学
- 传感器技术 传感器技术
背景情况:
- 低成本的空气质量传感器需要与参考仪器进行校准.
- 传感器同位点校准的最佳持续时间尚未确定.
- 多重污染物传感器可以测量颗粒物 (PM2.5),CO,NO2,O3和NO.
研究的目的:
- 为了确定低成本空气质量传感器的最佳校准周期持续时间.
- 评估环境因素和交叉敏感性如何影响校准准确度.
- 为了最大限度地减少协同位置的持续时间,同时保持可靠的传感器性能.
主要方法:
- 一个多重污染物传感器与参考仪器一起放置一年.
- 校准方程是使用1至180天的同位点子集开发的.
- 评估了根平均平方误差 (RMSE) 和皮尔森相关系数 (r).
主要成果:
- 最佳校准时间因传感器类型和环境条件而异.
- 在超过六周的校准期内,观察到减少RMSE的改善.
- 精确的校准可以在一周的时间内在战略性地选择的代表性条件下实现.
结论:
- 传感器校准的持续时间可以通过战略性选择的共同位置的时间最小化.
- 校准周期应包括各种环境条件,以提高准确性.
- 优化的共同定位策略提高了低成本传感器网络的可靠性和成本效益.
相关概念视频
Electronic Distance Measuring Instruments
66
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short...
66
Temperature Measurement Sites
1.8K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.8K
Instrument Calibration
226
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
226
Calibration Curves: Linear Least Squares
1.4K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
1.4K
Field Application of Global Positioning System
72
The Global Positioning System (GPS) has become an indispensable tool in fieldwork, offering unparalleled precision and efficiency for surveying, navigation, and infrastructure development. By harnessing signals from a constellation of satellites, GPS receivers determine the location of objects with remarkable speed and accuracy, often completing calculations within a second.Advantages of Modern GPS TechnologyContemporary GPS receivers are designed to meet the practical demands of field...
72
Calibration Curves: Correlation Coefficient
1.7K
In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
1.7K