回声阶段对瓶鼻海豚震动回声检测的影响
James J Finneran1, Madelyn G Strahan2, Jason Mulsow2
1U.S. Navy Marine Mammal Program, Naval Information Warfare Center Pacific Code 56710, 53560 Hull Street, San Diego, California 92152, USA.
The Journal of the Acoustical Society of America
|June 17, 2023
概括
玻璃鼻海豚可以检测回声阶段的微妙变化,显示出一种复杂的能力,以感知声音中的细节. 这项研究突出了它们用于回声定位的高级听觉处理能力.
科学领域:
- 海洋生物学 海洋生物学
- 生物声学是一种生物声学.
- 动物行为 动物行为
背景情况:
- 玻璃鼻海豚 (Tursiops truncatus) 在导航和食方面严重依赖回声定位.
- 了解回声处理的细节对于破译他们的感官世界至关重要.
研究的目的:
- 为了研究瓶鼻海豚对回声相变化的敏感性.
- 确定回声细结构在海豚听觉感知中的作用.
主要方法:
- 一个的回声范式被采用,呈现海豚与改变回声延迟和阶段.
- 海豚被训练在检测回声特征的变化时发出声音.
- 测试的各种条件包括动延迟,相位变化 (±45°,0°-180°),交替变化和随机相位变化.
主要成果:
- 当回声细结构相似但外不同时,海豚的歧视性降低了.
- 观察到高性能与相同的包裹,但不同的精细结构.
- 随机相位移显著增加了回声检测值,表明对一致细结构的敏感性.
- 性能与假设的连贯接收器一致,尽管并不严格必要.
结论:
- 玻璃鼻海豚对回声的微妙结构具有高度的敏感性.
- 它们的听觉系统可以区分回声阶段的微妙变化,这对于解释声学信息至关重要.
- 这种灵敏度有助于区分物体和使用回声定位在复杂的环境中导航.
相关概念视频
Echo
540
The human ear cannot distinguish between two sources of sound if they happen to reach within a specific time interval, typically 0.1 seconds apart. More than this, and they are perceived as separate sources.
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
540
¹H NMR: Interpreting Distorted and Overlapping Signals
1.1K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.1K
Difference from Background: Limit of Detection
6.7K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
The LOD indicates the presence or absence...
6.7K
Effects of EDTA on End-Point Detection Methods
314
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
314
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
1.1K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.1K