In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
720
验证一种临床上适用的设备,用于快速准确地量化血液体积
Andreas Breenfeldt Andersen1, Thomas C Bonne2, Joar Hansen3
1Department of Public Health, Research Unit for Exercise Biology, Aarhus University, Aarhus, Denmark.
Journal of clinical laboratory analysis
|June 19, 2023
概括
一个新的半自动设备使用一氧化碳再呼吸精确测量血液体积 (BV),与双同位素方法相对应. 这种更快,无痕迹剂的方法可以在临床环境中频繁监测BV.
科学领域:
- 身体生理学 身体生理学
- 医疗器械 医疗器械
- 诊断方法 诊断方法
背景情况:
- 传统的双同位素法用于血液体积 (BV) 测定,因同位素半衰期长而受到限制.
- 一氧化碳 (CO) 再呼吸程序已经在实验室中使用了100年,使频繁的BV测量成为可能.
研究的目的:
- 评估半自动化CO再呼吸装置用于血液体积 (BV) 测量的可靠性和准确性.
- 为了比较二氧化碳再呼吸装置与已建立的双同位素方法.
- 评估该设备检测血液体积中已知小变化的能力.
主要方法:
- 研究了一种用于血液体积 (BV) 测定的半自动化CO再呼吸装置.
- 与A研究中的双同位素技术对比的设备测量 (2分钟和10分钟协议)
- 在B研究中,通过测量其检测BV减少2%的能力来评估设备的准确性.
主要成果:
- 在CO再呼吸方案和双同位素方法 (p < 0.001) 之间发现了高相关性 (r2 = 0.89-0.98).
- 双同位素方法产生的BV值较低 (425-491毫升,p<0.001),相比于CO再呼吸.
- 该装置准确量化了150 ± 45毫升 (p < 0.001) 的BV减少,相当于2%的变化.
结论:
- 半自动化CO再呼吸装置准确地测量血液体积 (BV) 的小变化 (2%).
- 该方法与双同位素技术具有很高的相关性.
- 由于速度 (~15分钟),无放射性痕迹物以及适合重复测量而具有临床意义.
相关概念视频
Equipments Used To Measure Blood Pressure
1.1K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
1.1K
Glassware Calibration
295
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
295
Blood Flow
70.4K
Blood is pumped by the heart into the aorta, the largest artery in the body, and then into increasingly smaller arteries, arterioles, and capillaries. The velocity of blood flow decreases with increased cross-sectional blood vessel area. As blood returns to the heart through venules and veins, its velocity increases. The movement of blood is encouraged by smooth muscle in the vessel walls, the movement of skeletal muscle surrounding the vessels, and one-way valves that prevent backflow.
70.4K