使用JVP dome进行触觉功能评估的协议:可行性研究和初步结果
Yung-Jung Wang1,2, Chung-Tung Sung1,2, Jian-Jia Huang3,4,5
1School of Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
Brain and behavior
|June 19, 2023
概括
使用楼梯方法开发了一个用于格子定向任务的新协议. 该方法有效地评估触觉空间敏度,平均值为1.8毫米.
科学领域:
- 神经科学是一个神经科学.
- 感官感知是一种感官感知.
- 触觉学是一种触觉学.
背景情况:
- 触觉空间敏度对于对象感知至关重要.
- 联合民进党的圆顶方便了格式化指导任务.
- 现有的协议缺乏实践,培训和测试的详细序列.
研究的目的:
- 提出并详细介绍一个格子定向任务协议.
- 为了有效地估计值,使用楼梯方法.
- 与恒定刺激方法相比,以较少的试验来确保任务质量.
主要方法:
- 招募了23名健康参与者.
- 使用了11个槽宽度的JVP圆顶.
- 一个两下一上楼梯方法估计了触觉歧视值.
主要成果:
- 参与者成功完成了实践和培训.
- 平均触觉区分值为1.8 ± 0.75毫米.
- 该议定书有效评估了触觉歧视值.
结论:
- 开发的协议有效地评估了触觉空间敏度.
- 该协议证明了未来临床应用的可行性.
相关概念视频
Assessment of the Cardiovascular System III: Palpation
394
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
394
Assessment of the Abdomen III: Palpation
831
Palpation is a crucial tactile examination method for assessing abdominal organs and detecting conditions like tenderness, distention, masses, or fluid. It involves both light and deep palpation techniques, each serving specific diagnostic purposes. Light palpation helps identify tenderness and other surface-level indicators, while deep palpation locates and assess abdominal masses and organ boundaries. A skilled professional can gather valuable insights through palpation, including evaluating...
831
Physical Assessment of the Respiratory Tract II: Palpation
439
Physical assessment of the respiratory tract is critical in identifying potential health issues. One key component of this assessment is palpation, a technique healthcare providers use to assess the body for abnormalities. This content explores the method of palpation in evaluating the respiratory tract, focusing on thoracic palpation and tactile fremitus.
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
439
Pulse Assessment Sites
1.2K
Pulse assessment sites are crucial in evaluating a patient's cardiovascular health. By assessing the pulsations of arteries at specific anatomical locations, healthcare professionals can gather valuable information about blood flow, heart rate, and peripheral circulation. Understanding these pulse assessment sites is essential for conducting comprehensive cardiovascular evaluations and monitoring patients' overall health. These sites are strategically chosen due to the accessibility and...
1.2K
Assessment of apical radial pulse
802
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
802
Assessment of apical pulse
1.0K
Assessing the Apical Pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
1.0K